{"schemaVersion":2,"meta":{"id":"kirschstr41","name":"Kirschstraße 41","ausgabe":25,"stand":"2026-09-05","address":"Kirschstraße 41, 13158 Berlin-Rosenthal","bauherr":"Ivan Gorb","norm":"DIN EN IEC 61439-3:2025-06","katalog":{"id":"2026-09-08","engine_commit":"82ce908","gerechnet_am":"2026-09-13T08:39:02+00:00"},"src":"v19 rebuild (UV1 aus v18; UV-Keller/EG/OG ergänzt); Steuerung, Lichtkonzept, Betriebsarten und Wechselrichter-Pass aus dem Planungsdokument v19"},"gebaeude":{"typ":"haus","adresse":"Kirschstraße 41, 13158 Berlin-Rosenthal","etagen":[{"id":"keller","level":-1,"name":"Keller","hoehe_m":2.5,"b_m":10,"l_m":10,"flaeche_m2":112.5,"anbauten":[{"id":"keller-a1","seite":"sued","abstand_m":5,"breite_m":5,"tiefe_m":2.5,"name":"Под террасой"}],"raeume":[{"id":"keller-r2","name":"Санузел","art":"bad","marke":[3.45,5.050000000000001],"flaeche_m2":8},{"id":"keller-r4","name":"Техпомещение/прачечная","art":"hwr","marke":[0.15000000000000002,3.95],"flaeche_m2":15},{"id":"keller-r3","name":"Лестница вверх","art":"treppe","marke":[5.050000000000001,5.15],"flaeche_m2":4},{"id":"keller-r5","name":"Тренажерный зал","art":"sonstig","marke":[3.5500000000000003,0.050000000000000266],"flaeche_m2":16},{"id":"keller-r6","name":"Гостевая","art":"sonstig","marke":[0.05,0.050000000000000266],"flaeche_m2":16},{"id":"keller-r7","name":"Коридор","art":"flur","marke":[2.0500000000000003,3.95]},{"id":"keller-r8","name":"Хозблок","art":"abstellraum","marke":[5.050000000000001,-2.45],"flaeche_m2":12.5},{"id":"keller-r9","name":"Бюро","art":"buero","marke":[6.95,0.050000000000000266],"flaeche_m2":34}],"moebel":[{"id":"f-72f8a4c8fae7a74d21c9c00dae92e8fc","asset":"bed","catalogVersion":"1.0.0","xy":[1.15,1.9],"width_m":1.7000000000000002,"depth_m":2.1,"rotation":90,"color":"#2f1e14","room":"keller-r6","sleeping_m":[1.6,2]},{"id":"f-6a82806e55c8e47b79b207f05eeee33c","asset":"toilet","catalogVersion":"1.0.0","xy":[4.2,5.425],"width_m":0.38,"depth_m":0.65,"rotation":180,"color":"#c5b7a5","room":"keller-r2"},{"id":"f-f68e69f3dab82d92eaa24943f2b44b95","asset":"shower-corner","catalogVersion":"1.0.0","xy":[4.39,9.3],"width_m":0.9,"depth_m":0.9,"rotation":270,"color":"#c5b7a5","room":"keller-r2"},{"id":"f-9c65692b165693ab7244541f58046592","asset":"basin","catalogVersion":"1.0.0","xy":[4.615,7.2],"width_m":0.6,"depth_m":0.45,"rotation":270,"color":"#c5b7a5","room":"keller-r2"}],"punkte":[{"id":"keller-p1","art":"steckdose","raum":"keller-r2","anzahl":2},{"id":"keller-p2","art":"licht","raum":"keller-r2"},{"id":"keller-p3","art":"steckdose","raum":"keller-r8","anzahl":1},{"id":"keller-p4","art":"licht","raum":"keller-r4"},{"id":"keller-p5","art":"steckdose","raum":"keller-r4","anzahl":3},{"id":"keller-p6","art":"waschmaschine","raum":"keller-r4"},{"id":"keller-p7","art":"trockner","raum":"keller-r4"},{"id":"keller-p8","art":"licht","raum":"keller-r2"},{"id":"keller-p9","art":"steckdose","raum":"keller-r2"},{"id":"keller-p10","art":"dusch_wc","raum":"keller-r2"},{"id":"keller-p11","art":"lueftung","raum":"keller-r2","name":"Abluftventilator","src":"Eigentümer 22.09.2026: an dieser Stelle sitzt ein Abluftventilator, kein Lüftungsgerät mit Wärmerückgewinnung. Hersteller, Typ, Leistung und Stromkreis nachzutragen — ohne sie zählt die Stelle nicht als Verbraucher ihres Kreises (§9 E1)."},{"id":"keller-p12","art":"bewegungsmelder","raum":"keller-r2"},{"id":"keller-p13","art":"licht","raum":"keller-r4"},{"id":"keller-p14","art":"steckdose","raum":"keller-r4","anzahl":3},{"id":"keller-p15","art":"waschmaschine","raum":"keller-r4","anzahl":2},{"id":"keller-p16","art":"trockner","raum":"keller-r4"},{"id":"keller-p17","art":"lueftung","raum":"keller-r4","name":"Abluftventilator","src":"Eigentümer 22.09.2026: an dieser Stelle sitzt ein Abluftventilator, kein Lüftungsgerät mit Wärmerückgewinnung. Hersteller, Typ, Leistung und Stromkreis nachzutragen — ohne sie zählt die Stelle nicht als Verbraucher ihres Kreises (§9 E1)."},{"id":"keller-p18","art":"licht","raum":"keller-r3","anzahl":2},{"id":"keller-p19","art":"bewegungsmelder","raum":"keller-r3"},{"id":"keller-p20","art":"licht","raum":"keller-r5"},{"id":"keller-p21","art":"steckdose","raum":"keller-r5","anzahl":2},{"id":"keller-lw1","art":"lueftung","raum":"keller-r5","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF10","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis KF10; Raumzuordnung im Keller vom Planer vorgeschlagen (Sport, Gäste, Büro, HWR) — vom Eigentümer zu bestätigen"},{"id":"keller-lw2","art":"lueftung","raum":"keller-r6","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF10","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis KF10; Raumzuordnung im Keller vom Planer vorgeschlagen (Sport, Gäste, Büro, HWR) — vom Eigentümer zu bestätigen"},{"id":"keller-lw3","art":"lueftung","raum":"keller-r9","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF11","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis KF11; Raumzuordnung im Keller vom Planer vorgeschlagen (Sport, Gäste, Büro, HWR) — vom Eigentümer zu bestätigen"},{"id":"keller-lw4","art":"lueftung","raum":"keller-r4","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF11","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis KF11; Raumzuordnung im Keller vom Planer vorgeschlagen (Sport, Gäste, Büro, HWR) — vom Eigentümer zu bestätigen"},{"id":"keller-fc1","art":"fancoil","raum":"keller-r5","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF10","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"keller-fc2","art":"fancoil","raum":"keller-r6","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF10","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"keller-fc3","art":"fancoil","raum":"keller-r9","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF11","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"keller-fc4","art":"fancoil","raum":"keller-r4","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF11","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"wkf1-g","art":"waschmaschine","raum":"keller-r4","name":"Waschmaschine","leistung_W":2200,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF1","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wkf2-g","art":"trockner","raum":"keller-r4","name":"Waschtrockner","leistung_W":2700,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF2","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wkf8-l","art":"licht","raum":"keller-r2","name":"Licht Keller (LED, 6 Räume, 56.5 m²)","leistung_W":570,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF8","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."},{"id":"wkf9-l","art":"licht","raum":"keller-r4","name":"Licht Garage/Büro (LED, 2 Räume, 49 m²)","leistung_W":490,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF9","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."},{"id":"wkf17-l","art":"aussen","raum":"keller-r7","name":"Terrasse Licht 230 V (LED, 6 Leuchten × 12 W)","leistung_W":72,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF17","src":"Annahme des Planers 22.09.2026: LED-Aussenleuchten, übliche Anschlussleistung je Leuchte 12 W. Kein Leuchtenverzeichnis im Projekt; Zahl der Leuchten aus dem Namen des Kreises geschätzt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1 — mit der Leuchtenliste des Eigentümers zu ersetzen."},{"id":"wkf18-l","art":"aussen","raum":"keller-r7","name":"Aussenlicht Front: Carport, Adresse, Weg (LED, 5 Leuchten × 12 W)","leistung_W":60,"phasen":1,"anzahl":1,"verteiler":"uv-keller","stromkreis":"WKF18","src":"Annahme des Planers 22.09.2026: LED-Aussenleuchten, übliche Anschlussleistung je Leuchte 12 W. Kein Leuchtenverzeichnis im Projekt; Zahl der Leuchten aus dem Namen des Kreises geschätzt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1 — mit der Leuchtenliste des Eigentümers zu ersetzen."}],"waende":[{"id":"keller-w1","von":[5,0],"nach":[10,0]},{"id":"keller-w2","von":[6.9,0],"nach":[6.9,10]},{"id":"keller-w4","von":[5,5],"nach":[5,10]},{"id":"keller-w5","von":[3.4,5],"nach":[3.4,10]},{"id":"keller-w6","von":[0.1,3.9],"nach":[6.9,3.9]},{"id":"keller-w7","von":[3.5,3.9],"nach":[3.5,0]},{"id":"keller-w8","von":[5,10],"nach":[6.9,10]},{"id":"keller-w9","von":[6.9,10],"nach":[6.9,3.9]},{"id":"keller-w10","von":[6.9,3.9],"nach":[2,3.9]},{"id":"keller-w12","von":[2,3.9],"nach":[2,5]},{"id":"keller-w13","von":[2,5],"nach":[5,5]},{"id":"keller-w16","von":[3.5,3.9],"nach":[6.9,3.9]},{"id":"keller-w17","von":[6.9,3.9],"nach":[6.9,0]},{"id":"keller-w18","von":[6.9,0],"nach":[3.5,0]},{"id":"keller-w20","von":[6.9,10],"nach":[10,10]},{"id":"keller-w21","von":[10,10],"nach":[10,0]},{"id":"keller-w22","von":[10,0],"nach":[6.9,0]},{"id":"keller-w24","von":[3.4,10],"nach":[5,10]},{"id":"keller-w26","von":[5,5],"nach":[3.4,5]},{"id":"keller-w29","von":[0,10],"nach":[3.4,10]},{"id":"keller-w31","von":[3.4,5],"nach":[2,5]},{"id":"keller-w33","von":[2,3.9],"nach":[0.1,3.9]},{"id":"keller-w34","von":[0.1,3.9],"nach":[0.1,10]},{"id":"keller-w25","von":[5,10],"nach":[6.1,10]},{"id":"keller-w27","von":[6.1,10],"nach":[5.7,10]},{"id":"keller-w28","von":[5.7,10],"nach":[5.7,5.1]},{"id":"keller-w30","von":[5.7,5.1],"nach":[5,5.1]},{"id":"keller-w32","von":[5,5],"nach":[5.7,5]},{"id":"keller-w35","von":[0.1,3.9],"nach":[3.5,3.9]},{"id":"keller-w36","von":[3.5,0],"nach":[0,0]},{"id":"keller-w37","von":[0,0],"nach":[0,3.9]}],"src":"Paket v18 Dok 06 W9 (UV Keller)"},{"id":"eg","level":0,"name":"Erdgeschoss","hoehe_m":2.5,"b_m":10,"l_m":10,"flaeche_m2":112.5,"anbauten":[{"id":"eg-a1","seite":"ost","abstand_m":5,"breite_m":5,"tiefe_m":2.5,"name":"Терраса / зимний сад"}],"raeume":[{"id":"eg-r1","name":"Кухня гостинная","art":"kueche","flaeche_m2":32},{"id":"eg-r2","name":"Спальня 1","art":"schlafen","flaeche_m2":15},{"id":"eg-r3","name":"Спальня 2","art":"kind","flaeche_m2":16},{"id":"eg-r4","name":"Женский санузел","art":"bad","flaeche_m2":12},{"id":"eg-r5","name":"Мужской санузел","art":"bad","flaeche_m2":7},{"id":"eg-r6","name":"Лестничное пространство","art":"treppe","flaeche_m2":4},{"id":"eg-r7","name":"Прихожая","art":"sonstig","flaeche_m2":3.5},{"id":"eg-r8","name":"Коридор","art":"flur"},{"id":"eg-r9","name":"Столовая","art":"balkon","flaeche_m2":12.5},{"id":"eg-r10","name":"Гардероб","art":"sonstig","flaeche_m2":3}],"punkte":[{"id":"eg-lw5","art":"lueftung","raum":"eg-r1","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis EF12"},{"id":"eg-lw6","art":"lueftung","raum":"eg-r2","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis EF12"},{"id":"eg-lw7","art":"lueftung","raum":"eg-r3","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis EF12"},{"id":"eg-fc5","art":"fancoil","raum":"eg-r1","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"eg-fc6","art":"fancoil","raum":"eg-r2","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"eg-fc7","art":"fancoil","raum":"eg-r3","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF12","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"wef1-g","art":"herd","raum":"eg-r1","name":"Kochfeld Induktion","leistung_W":8200,"phasen":3,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF1","src":"Datenblattwert steht im Namen des Verbrauchers (Ausführungspaket v18): «Kochfeld Induktion 8,2 kW»"},{"id":"wef2-g","art":"backofen","raum":"eg-r1","name":"Dampf-/Backofen","leistung_W":3500,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF2","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wef3-g","art":"sonstig","raum":"eg-r1","name":"Mikrowelle + Grill","leistung_W":1500,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF3","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wef4-g","art":"spuelmaschine","raum":"eg-r1","name":"Geschirrspüler","leistung_W":2200,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF4","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wef5-g","art":"dunstabzug","raum":"eg-r1","name":"Kaffeemaschine + Dunstabzug","leistung_W":1700,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF5","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern."},{"id":"wef6-g","art":"sonstig","raum":"eg-r1","name":"Kühlgeräte × 3","leistung_W":300,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF6","src":"Annahme des Planers 22.09.2026: übliche Geräteleistung dieser Bauart, kein Typenschild im Projekt. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach PLANER-REGELN §9 E1. Vom Eigentümer am Typenschild zu bestätigen — dann Quelle auf das Gerät ändern. Drei Geräte zu je 100 W."},{"id":"wef10-l","art":"licht","raum":"eg-r1","name":"Licht A EG (LED, 4 Räume, 51 m²)","leistung_W":510,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF10","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."},{"id":"wef11-l","art":"licht","raum":"eg-r2","name":"Licht B EG (LED, 6 Räume, 54 m²)","leistung_W":540,"phasen":1,"anzahl":1,"verteiler":"uv-eg","stromkreis":"WEF11","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."}],"waende":[{"id":"eg-w1","von":[5,10],"nach":[5,4.9]},{"id":"eg-w2","von":[5,4.9],"nach":[5,3.8]},{"id":"eg-w3","von":[5,3.8],"nach":[10,3.8]},{"id":"eg-w4","von":[5,3.8],"nach":[5,0]},{"id":"eg-w5","von":[0,4.9],"nach":[2.5,4.9]},{"id":"eg-w8","von":[2.5,2.4],"nach":[5,2.4]},{"id":"eg-w9","von":[0,6],"nach":[3.8,6]},{"id":"eg-w10","von":[3.8,6],"nach":[3.8,4.9]},{"id":"eg-w11","von":[0,7.4],"nach":[5,7.4]},{"id":"eg-w12","von":[2.1,7.4],"nach":[2.1,6]},{"id":"eg-w13","von":[2.1,7.4],"nach":[5,7.4]},{"id":"eg-w14","von":[5,7.4],"nach":[5,4.9]},{"id":"eg-w15","von":[5,4.9],"nach":[5,3.7]},{"id":"eg-w16","von":[3.8,4.9],"nach":[3.8,2.4]},{"id":"eg-w17","von":[2.5,4.9],"nach":[3.8,4.9]},{"id":"eg-w18","von":[2,2.4],"nach":[2.5,2.4]},{"id":"eg-w19","von":[2,4.9],"nach":[2,0]},{"id":"eg-w20","von":[10,5],"nach":[10,10]}],"src":"Paket v18 Dok 06 W10 (UV Erdgeschoss)"},{"id":"og","level":1,"name":"Obergeschoss","hoehe_m":2.5,"b_m":10,"l_m":6,"flaeche_m2":60,"raeume":[{"id":"og-r2","name":"Спальня 4","art":"schlafen","marke":[6.050000000000001,0.05],"flaeche_m2":18},{"id":"og-r1","name":"Спальня 3","art":"schlafen","marke":[0.05,0.05],"flaeche_m2":24},{"id":"og-r3","name":"Санузел","art":"bad","marke":[2.75,0.05],"flaeche_m2":14},{"id":"og-r4","name":"Коридор","art":"flur","marke":[5.050000000000001,2.15]}],"punkte":[{"id":"og-p1","art":"licht","raum":"og-r2"},{"id":"og-p2","art":"steckdose","raum":"og-r2","anzahl":4},{"id":"og-p3","art":"licht","raum":"og-r1"},{"id":"og-p4","art":"steckdose","raum":"og-r1","anzahl":4},{"id":"og-p5","art":"licht","raum":"og-r3"},{"id":"og-p6","art":"steckdose","raum":"og-r3"},{"id":"og-p7","art":"dusch_wc","raum":"og-r3"},{"id":"og-p8","art":"lueftung","raum":"og-r3","name":"Abluftventilator","src":"Eigentümer 22.09.2026: an dieser Stelle sitzt ein Abluftventilator, kein Lüftungsgerät mit Wärmerückgewinnung. Hersteller, Typ, Leistung und Stromkreis nachzutragen — ohne sie zählt die Stelle nicht als Verbraucher ihres Kreises (§9 E1)."},{"id":"og-p9","art":"bewegungsmelder","raum":"og-r3"},{"id":"og-lw8","art":"lueftung","raum":"og-r1","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF5","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis OF5"},{"id":"og-lw9","art":"lueftung","raum":"og-r2","name":"Dezentrales Lüftungsgerät mit WRG","leistung_W":6.5,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF5","src":"Eigentümer 15.09.2026: dezentrales Lüftungsgerät mit WRG (Technical Parameters: 4,7/5,6/6,5 W, 30/50/60 m³/h, Ø 158 mm; dokumente/lueftung-dezentral-wrg-technical-parameters-2026-09-15.md; Hersteller/Typ nachzutragen); elektrisch am Fancoil-Kreis OF5"},{"id":"og-fc8","art":"fancoil","raum":"og-r1","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF5","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"og-fc9","art":"fancoil","raum":"og-r2","name":"Fancoil FP-2PLY (Wand)","leistung_W":33,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF5","src":"Datenblatt SPRSUN, Seite 55 «Parameter of Wall Hanging FCU FP-2PLY» (datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf, S. 3 des Projektauszugs): Power Input 33W, Cooling Cap 3.6KW, Heating Cap 5.4KW, Air Flow 680m³/h, Welling DC motor, Net Size 890*315*188mm, 9.3KG. Die Seite ist ein Bild ohne Textschicht; die Werte wurden am 22.09.2026 an der gerenderten Seite selbst nachgelesen (vorher nur «read by eye» im INDEX). Raumzuordnung: Planer-Vorschlag — ein Fancoil je Raum, in dem auch ein Lüftungsgerät sitzt, am selben Kreis; vom Eigentümer zu bestätigen."},{"id":"wof3-l","art":"licht","raum":"og-r1","name":"Licht A OG (LED, 2 Räume, 42 m²)","leistung_W":420,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF3","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."},{"id":"wof4-l","art":"licht","raum":"og-r3","name":"Licht B OG (LED, 2 Räume, 14 m²)","leistung_W":140,"phasen":1,"anzahl":1,"verteiler":"uv-og","stromkreis":"WOF4","src":"Annahme des Planers 22.09.2026: LED-Beleuchtung mit 10 W je Quadratmeter Nutzfläche (Entscheidung des Eigentümers 22.09.2026 — statt der zuerst angesetzten 6 W/m²; DIN EN 12464-1 gibt Beleuchtungsstärken, keine Anschlussleistung). Fläche aus gebaeude.etagen[].raeume. Ersetzt die Platzhalter-Last des Ausführungspakets (In des Schutzorgans) nach §9 E1. Mit der Leuchtenliste des Eigentümers zu ersetzen."}],"waende":[{"id":"og-w1","von":[6,6],"nach":[6,0]},{"id":"og-w4","von":[2.7,3],"nach":[2.7,6]},{"id":"og-w5","von":[2.7,6],"nach":[2.7,0]},{"id":"og-w6","von":[5,6],"nach":[5,2.1]},{"id":"og-w7","von":[5,2.1],"nach":[2.8,2.1]},{"id":"og-w8","von":[2.8,2.1],"nach":[6,2.1]}],"src":"Paket v18 Dok 06 W11 (UV Obergeschoss)"}],"nutzung":{"ereignisse":[{"id":"licht-schlafzimmer","name":"Licht Schlafzimmer (4)","art":"licht","von_h":6,"dauer_h":1,"kreise":["WEF11","WOF3","WOF4"],"faktor":0.4,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,40: nicht alle Leuchten eines Kreises brennen gleichzeitig."},{"id":"licht-baeder","name":"Licht Bäder (4)","art":"licht","von_h":6.17,"dauer_h":1,"kreise":["WKF8"],"faktor":0.4,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,40: nicht alle Leuchten eines Kreises brennen gleichzeitig."},{"id":"duschen","name":"Duschen: 4 Bäder × 50 l warm","art":"warmwasser","von_h":6.17,"dauer_h":1,"liter":200,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"abluft-morgen","name":"Abluftventilatoren Bäder","art":"lueftung","von_h":6.17,"dauer_h":1.5,"leistung_W":45,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"kochen-morgen","name":"Frühstück: Kochfeld + Mikrowelle","art":"kochen","von_h":6.5,"dauer_h":0.75,"kreise":["WEF1","WEF3","WEF5"],"faktor":0.35,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,35: Kochfelder und Kühlgeräte takten — der Anschlusswert fliesst nur bruchteilig (übliche Planungsannahme)."},{"id":"kuehlgeraete","name":"Kühlschrank + Gefrierschrank","art":"dauerlast","von_h":0,"dauer_h":24,"kreise":["WEF6"],"faktor":0.35,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,35: Kochfelder und Kühlgeräte takten — der Anschlusswert fliesst nur bruchteilig (übliche Planungsannahme)."},{"id":"steuerung","name":"EMS, Türsprechanlage, Heizungspumpe","art":"dauerlast","von_h":0,"dauer_h":24,"leistung_W":70,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"kochen-mittag","name":"Mittag: Kochfeld + Backofen","art":"kochen","von_h":15,"dauer_h":1,"kreise":["WEF1","WEF2"],"faktor":0.35,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,35: Kochfelder und Kühlgeräte takten — der Anschlusswert fliesst nur bruchteilig (übliche Planungsannahme)."},{"id":"ww-mittag","name":"Warmwasser Küche/Hände","art":"warmwasser","von_h":15,"dauer_h":1,"liter":20,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"kochen-abend","name":"Abendessen: Kochfeld, Backofen, Dunstabzug","art":"kochen","von_h":19,"dauer_h":1.25,"kreise":["WEF1","WEF2","WEF5"],"faktor":0.35,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,35: Kochfelder und Kühlgeräte takten — der Anschlusswert fliesst nur bruchteilig (übliche Planungsannahme)."},{"id":"licht-abend","name":"Licht Wohnbereich und Flure","art":"licht","von_h":17,"dauer_h":6,"kreise":["WEF10","WEF11","WKF9"],"faktor":0.4,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,40: nicht alle Leuchten eines Kreises brennen gleichzeitig."},{"id":"licht-aussen","name":"Aussenlicht","art":"licht","von_h":17,"dauer_h":6,"kreise":["WKF17","WKF18"],"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"arbeitsplaetze","name":"Rechner, Monitore, Fernseher","art":"geraet","von_h":17,"dauer_h":6,"leistung_W":600,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"ww-abend","name":"Warmwasser Abend (Küche, Bad)","art":"warmwasser","von_h":19,"dauer_h":2,"liter":60,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert."},{"id":"spuelmaschine","name":"Geschirrspüler nach dem Abendessen","art":"geraet","von_h":20.5,"dauer_h":1.5,"kreise":["WEF4"],"faktor":0.45,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,45: Wasch- und Spülmaschinen ziehen ihre Leistung nur in der Heizphase."},{"id":"lueftung-nacht","name":"Lüftungsgeräte WRG (Nacht)","art":"lueftung","von_h":22,"dauer_h":8,"leistung_W":58.5,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert. Berichtigt 22.09.2026: neun Lüftungsgeräte à 6,5 W = 58,5 W. Die Kreise WKF10/WKF11/WEF12/WOF5 tragen auch die Fancoils — die laufen mit der Heizung, nicht mit dem Lüftungsprogramm."},{"id":"lueftung-abend","name":"Lüftungsgeräte WRG (Abend)","art":"lueftung","von_h":17,"dauer_h":4,"leistung_W":58.5,"faktor":1,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 1: Anschlusswert gleich Betriebswert. Berichtigt 22.09.2026: neun Lüftungsgeräte à 6,5 W = 58,5 W. Die Kreise WKF10/WKF11/WEF12/WOF5 tragen auch die Fancoils — die laufen mit der Heizung, nicht mit dem Lüftungsprogramm."},{"id":"waschen","name":"Waschmaschine und Waschtrockner (2× die Woche)","art":"geraet","von_h":10,"dauer_h":3,"kreise":["WKF1","WKF2"],"faktor":0.13,"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers. Ausnutzungsgrad 0,45: Wasch- und Spülmaschinen ziehen ihre Leistung nur in der Heizphase. Berichtigt 22.09.2026: 0,45 Ausnutzung × 2 von 7 Tagen = 0,13 als Tagesmittel — gewaschen wird zweimal die Woche, gerechnet wird jeder Tag."}],"src":"Beschreibung des Eigentümers 22.09.2026: Licht 6:00 in den Schlafzimmern, 6:10 in den Bädern, gleichzeitig die Duschen (50 l warm je Bad, 6 l kalt), Abluft dazu; gekocht wird dreimal — 6:30, 15:00, 19:00; danach geht das Haus aus dem Haus; abends Rechner, Monitore, Fernseher; Kühlschrank und Gefrierschrank laufen durch; die Lüftungsgeräte nach eigenem Programm nachts/früh und abends. Leistungen der Endgeräte, wo kein Typenschild vorliegt, sind Annahmen des Planers."},"bewohner":5,"lat":52.593,"lon":13.383,"bauweise":"holzstaender","daemmung":{"vorhanden":true,"stoff":"mineralwolle","leitungen_in_daemmung":true},"huelle":{"bauteile":[{"id":"wand-eg","name":"Aussenwand Erdgeschoss","art":"wand","schichten":[{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.032,"im_gefach":true},{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.04}],"flaeche_m2":75.50999999999999,"holzanteil":0.15,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"wand-og","name":"Aussenwand Obergeschoss","art":"wand","schichten":[{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.032,"im_gefach":true},{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.04}],"flaeche_m2":69.3,"holzanteil":0.15,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"wand-keller","name":"Kellerwand","art":"kellerwand","schichten":[{"stoff":"Mauerwerk","dicke_mm":240,"lambda":0.8},{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.04}],"flaeche_m2":98.22999999999999,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a — Stärke und Steinart des Mauerwerks nicht angegeben, 240 mm bei λ 0,80 angenommen"},{"id":"decke-dachraum","name":"Decke zum Dachraum","art":"decke","schichten":[{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.034,"im_gefach":true},{"stoff":"Mineralwolle","dicke_mm":100,"lambda":0.034}],"flaeche_m2":60,"holzanteil":0.12,"puffer":0.6,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a — der Dachraum ist kein kalter Boden: über ihm liegen 120 mm Mineralwolle λ 0,034 in den Sparren, daher Pufferfaktor 0,6 nach DIN EN ISO 13789 (angenommen)"},{"id":"kellerboden","name":"Kellerboden","art":"boden","schichten":[],"flaeche_m2":112.5,"u_wert":0.35,"puffer":0.5,"src":"Aufbau nicht angegeben; U 0,35 W/(m²·K) angenommen, Erdreich mit Faktor 0,5"}],"fenster":[{"id":"fe-kg-1","stueck":4,"breite_m":0.6,"hoehe_m":0.8,"etage":"keller","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-kg-2","stueck":1,"breite_m":2.3,"hoehe_m":2,"etage":"keller","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-kg-3","stueck":1,"breite_m":0.9,"hoehe_m":1.5,"etage":"keller","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-eg-1","stueck":4,"breite_m":0.7,"hoehe_m":1.7,"etage":"eg","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-eg-2","stueck":2,"breite_m":0.9,"hoehe_m":1.7,"etage":"eg","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-eg-3","stueck":1,"breite_m":2.3,"hoehe_m":3,"etage":"eg","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-te-1","stueck":3,"breite_m":2,"hoehe_m":2.3,"etage":"eg","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-te-2","stueck":1,"breite_m":0.9,"hoehe_m":2.3,"etage":"eg","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-og-1","stueck":1,"breite_m":2.3,"hoehe_m":1.7,"etage":"og","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-og-2","stueck":1,"breite_m":2.3,"hoehe_m":1.1,"etage":"og","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},{"id":"fe-og-3","stueck":2,"breite_m":0.8,"hoehe_m":1.1,"etage":"og","rahmen":"Aluminium mit thermischer Trennung","verglasung":"Zweischeiben-Isolierverglasung, zwei Kammern","src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"}],"lueftung":{"luftwechsel_1h":0.4,"infiltration_1h":0.1,"rueckgewinnung_pct":75,"geraete":12,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a — 12 dezentrale Geräte mit 75 % Rückgewinnung; Aufteilung 0,4 Anlage / 0,1 Infiltration angenommen, kein Blower-Door-Test"},"ww_kwh_m2a":12.5,"src":"Angaben des Eigentümers 10.09.2026, festgehalten in dokumente/gebaeudehuelle-angaben-eigentuemer-2026-09-10.md, sha256 020fdf018dcbcf7224a2a8353371d2772cc88b63ac85a6ffcafd54ed811ba87a"},"src":"Paket v18 Dok 01/06; Flächen und Höhen noch nicht aufgenommen. lat/lon: Nominatim/OpenStreetMap, Schwerpunkt der Postleitzahl 13158 Rosenthal, abgefragt 2026-09-10 — die Kirschstraße selbst führt OSM nicht; für PVGIS ausreichend, dessen TMY-Raster im Kilometerbereich liegt. Hausgenaue Geokodierung offen."},"netz":{"un_V":400,"u0_V":230,"sls_A":50,"ina_A":63,"fn_Hz":50,"form":"TN-S ab PEN-Aufteilung, 5-adrig — am HAK durch Stromnetz Berlin zu bestätigen (K-12)","ik_max_kA":null,"igrid_max_A":32,"tarif":{"tag_ct":32,"nacht_ct":22,"nacht_von_h":22,"nacht_bis_h":6,"einspeisung_ct":0,"src":"Angabe des Eigentümers 22.09.2026: Tag 32 ct/kWh, Nacht 22 ct/kWh, keine Einspeisevergütung. Das Nachtfenster 22:00–06:00 ist die übliche Lage eines Doppeltarifs und vom Eigentümer noch zu bestätigen — der Lieferant nennt es im Vertrag."},"einfuehrung":{"etage":"keller","art":"erdkabel"},"src":"Paket v18 Dok 02 §1, 13 Kopf"},"erzeugung":{"pv":[{"id":"pv-1","name":"Bereich 1","azimut_deg":-90,"neigung_deg":38,"modul":"Rizen","anzahl":12,"kwp":8.64,"wp_modul":720,"bifazial":true,"mppt":1,"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026; Modultyp: Angabe des Eigentümers vom 10.09.2026, docs/REGELN.md §2 «Топология энергетического модуля»; MPPT: Angabe des Eigentümers 13.09.2026 — je Dachseite 12 Module, jeder String an seinem eigenen MPP-Tracker (Ost → MPPT1, West → MPPT2; verschiedene Ausrichtungen getrennt)"},{"id":"pv-2","name":"Bereich 2","azimut_deg":90,"neigung_deg":38,"modul":"Rizen","anzahl":12,"kwp":8.64,"wp_modul":720,"bifazial":true,"mppt":2,"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026; Modultyp: Angabe des Eigentümers vom 10.09.2026, docs/REGELN.md §2 «Топология энергетического модуля»; MPPT: Angabe des Eigentümers 13.09.2026 — je Dachseite 12 Module, jeder String an seinem eigenen MPP-Tracker (Ost → MPPT1, West → MPPT2; verschiedene Ausrichtungen getrennt)"}],"wechselrichter":{"article":"SUN-20K-SG05LP3-EU-SM2","maker":"Deye","name":"Deye SUN-20K-SG05LP3-EU-SM2 mit integriertem NA-Schutz","klasse":"Hybrid, 3-phasig, LV 48 V","na_schutz":true,"zertifikat":{"norm":"VDE-AR-N 4105/11.18 + DIN VDE V 0124-100/06.20","tuev":"A3 50651320 0001","report":"CN24RWZ6 001","modellreihe":"SUN-14/15/16/18/20K-SG05LP3-EU-SM2","firmware_zertifiziert":"1076","firmware_werk":"1184","status":"vorhanden (angenommen) — Firmwarestand des gelieferten Geräts offen (Punkt 29)","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},"backup":{"typ":"whole-home über HI403R und internen Deye-Backup","umschaltzeit_ms":10,"passthrough_A":70,"ausgangsfehlerstrom_A":66.8,"ueberstrom_A":100,"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026; RMS/Spitze und Dauer im Inselbetrieb offen (K-3, Prüfbericht CN24O7S7 004)"},"ports":{"grid":"5×16 über F2","load":"zu HI403R Stellung II","batterie":"DC ≥ 50 mm²","pv":"2× MPPT"},"src":"Dok 03; Einheitenzertifikat A3 50651320 0001"},"speicher":{"chemie":"LFP 48 V LV","u_V":48,"kwh":48,"modul_max_A":300,"system_max_A":350,"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},"unterkonstruktion":"K2 SingleRail 36 (Solarvie AB-262808-29829) — Modul- und Falzklemme gegen die reale Eindeckung prüfen"},"verteiler":[{"id":"uv1","name":"UV1","knoten":[{"id":"SLS","art":"einspeisung","name":"SLS 50 A im Zählerplatz","src":"Dok 02 §1"},{"id":"Deye","art":"wechselrichter","name":"Deye SUN-20K-SG05LP3-EU-SM2 mit integriertem NA-Schutz","src":"Dok 03; Einheitenzertifikat A3 50651320 0001","ports":["Deye.GRID","Deye.LOAD"],"artikel":"SUN-20K-SG05LP3-EU-SM2","datenblatt":"deye/SUN-20K-SG05LP3-EU-SM2_Datenblatt_DE.pdf","steuerbar":{"art":"speicher","src":"erzeugung.speicher 48 kWh / 48 V; steuerung.insel_kW 16,5 als AC-seitige Obergrenze"}},{"id":"Wallbox","art":"verbraucher","name":"KEBA KeContact P40 11 kW","src":"Dok 06 W8, 11 L1; leistung_W 11000: KEBA KeContact P40 Technische Daten V1.02, 11-kW-Variante (16 A) — 15.09.2026","klasse":"wallbox","artikel":"KeContact P40","datenblatt":"keba/KeContact_P40_P40Pro_Technische_Daten_V1.02_DE.pdf","leistung_W":11000,"steuerbar":{"art":"dimmen","src":"KEBA KeContact P40, Technische Daten V1.02 de: \"Stromlimit ... 6 A, 8 A, 10 A, 16 A, 20 A, 32 A\" fuer die Baureihe; verbaut ist die 11-kW-Variante mit 16 A Nennstrom (Dok 06 W8 last_A 16), darum enden die Stufen bei 16 A. Pause als Geraetezustand (\"Fahrzeug angesteckt: 4 W (pausiert)\"); Schaltkontakt-Eingaenge X1.1/X1.2. Boden 6 A = steuerung.wallbox_14a_A (§14a EnWG).","stufen_A":[16,10,8,6],"boden_A":6}},{"id":"Wärmepumpe","art":"verbraucher","name":"Wärmepumpe SPRSUN CGK-040V4P","src":"Dok 06 W12; leistung_W 5050: SPRSUN CGK-040V4P Datenblatt S. 1 «Max Power Input 5.05 kW» — 15.09.2026","klasse":"waermeerzeuger","artikel":"CGK-040V4P","datenblatt":"sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf","leistung_W":5050,"steuerbar":{"art":"schalten","src":"steuerbare Verbrauchseinrichtung nach §14a EnWG; Datenblatt datasheets/sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf (13.09.2026): DC-Inverter-Verdichter, Max Current 10,66 A, 5,05 kW — Regelschnittstelle (Modbus/Stufen) des CGK-040V4P dort nicht belegt, daher weiter \"schalten\""}},{"id":"Heizstäbe","art":"verbraucher","name":"Heizstäbe über Schütz K1","src":"Dok 06 W13; leistung_W 6000: SPRSUN CGH-06HR150 Datenblatt S. 2 «Hot water electric heater 3KW + heating electric heater 3KW» — 15.09.2026","klasse":"waermeerzeuger","artikel":"CGH-06HR150","datenblatt":"sprsun/Heatpump_Hydronic_Tank_Wall_Fan_Coil_Unit.pdf","leistung_W":6000,"steuerbar":{"art":"schalten","src":"Abwurf über Schütz K1 (Dok 06 W13)"}},{"id":"Heizungspumpe","art":"verbraucher","name":"Heizungspumpe","src":"Dok 06 W14","klasse":"hilfsantrieb"},{"id":"EMS","art":"verbraucher","name":"Steuerkreis 24 V / EMS","src":"Dok 06 W15, 04 §5","klasse":"steuerung"},{"id":"UV-Keller","art":"unterverteilung","name":"UV Keller","src":"Dok 06 W9","ziel":"uv-keller"},{"id":"UV-EG","art":"unterverteilung","name":"UV Erdgeschoss","src":"Dok 06 W10","ziel":"uv-eg"},{"id":"UV-OG","art":"unterverteilung","name":"UV Obergeschoss","src":"Dok 06 W11","ziel":"uv-og"}],"geraete":[{"bmk":"T1","article":"STEP-PS/1AC/24DC/0.75","maker":"Phoenix","name":"Netzteil 24 V DC 0,75 A","ebene":"E0","src":"Dok 05 §3, 08 §1","te":2,"x_mm":[295,330],"tmax_C":70,"verlust":{"fix_W":3.6}},{"bmk":"K2…K7","article":"PLC-RSC-24DC/21","maker":"Phoenix","name":"6× Koppelrelais 24 V DC (K7 Goldkontakte 21AU)","ebene":"E0","src":"Dok 05 §3, 08 §1 (6×9 mA×24 V)","te":2.5,"x_mm":[330,373.8],"tmax_C":70,"verlust":{"fix_W":1.3}},{"bmk":"HI403R","article":"HI403R","maker":"Hager","name":"Umschalter I-0-II 63 A 4P (Service-Bypass)","ebene":"E1","src":"Dok 05 §3, 08 §1, 09 §5; Bauhöhe 116 mm und Baubreite 215 mm: HI403R.pdf Abmessungen (12 Module nominal, physisch 215 > 210 mm — HagerCAD-Lauf 15.09.2026: passt in kein 12-PLE-Feld, Punkt 34)","te":12,"x_mm":[47.5,262.5],"z_mm":97,"h_mm":116,"b_mm":215,"tmax_C":70,"verlust":{"fix_W":3.6},"icw_kA":2.5},{"bmk":"F9","article":"NBN340","maker":"Hager","name":"LS B40 3P → UV EG","ebene":"E1","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[295,347.5],"tmax_C":60,"verlust":{"p_W":10.1,"at_A":40},"schutz":{"t_s":5,"char":"B","in_A":40},"icn_kA":10},{"bmk":"F12","article":"NBN325","maker":"Hager","name":"LS B25 3P → UV OG","ebene":"E1","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[356.3,408.8],"tmax_C":60,"verlust":{"p_W":11,"at_A":25},"schutz":{"t_s":5,"char":"B","in_A":25},"icn_kA":10},{"bmk":"Q1","article":"HHA101H","maker":"Hager","name":"Leistungsschalter h3+ P160 4P, Ir 63 A","ebene":"E2","src":"Dok 05 §3, 07, 08 §1, 15 §5.2; Bauhöhe 130 mm: HHA101H.pdf Abmessungen","x_mm":[45,185],"z_mm":105,"h_mm":130,"tmax_C":70,"verlust":{"p_W":35.7,"at_A":100},"schutz":{"t_s":5,"ir_A":63,"ii_A":1500},"icu_kA":25,"ics_kA":20,"drehmoment_Nm":6},{"bmk":"F4","article":"NCN316","maker":"Hager","name":"LS C16 3P → Wärmepumpe","ebene":"E2","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[295,347.5],"tmax_C":60,"verlust":{"p_W":8.27,"at_A":16},"schutz":{"t_s":0.4,"char":"C","in_A":16},"icn_kA":10},{"bmk":"F6","article":"NCN320","maker":"Hager","name":"LS C20 3P → K1/Heizstäbe","ebene":"E2","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[356.3,408.8],"tmax_C":60,"verlust":{"p_W":8.04,"at_A":20},"schutz":{"t_s":0.4,"char":"C","in_A":20},"icn_kA":10},{"bmk":"F8","article":"NBN340","maker":"Hager","name":"LS B40 3P → UV Keller","ebene":"E2","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[417.5,470],"tmax_C":60,"verlust":{"p_W":10.1,"at_A":40},"schutz":{"t_s":5,"char":"B","in_A":40},"icn_kA":10},{"bmk":"P1","article":"SDM630-Modbus V3","maker":"Eastron","name":"Energiezähler 3P 100 A direkt","ebene":"E3","src":"Dok 05 §3, 08 §1 (konservativ, Datenblatt ≤2 W unbelegt)","te":4,"x_mm":[295,365],"tmax_C":55,"verlust":{"fix_W":6}},{"bmk":"F3","article":"CDB640E","maker":"Hager","name":"FI 40 A 30 mA Typ B 4P","ebene":"E3","src":"Dok 05 §3, 08 §1, 09 §5 (40 A bis 65 °C)","te":4,"x_mm":[373.8,443.8],"tmax_C":70,"verlust":{"p_W":6.77,"at_A":40},"iz_A":40,"inc_kA":10,"idm_kA":0.8},{"bmk":"K1","article":"ESB40-40N-06","maker":"ABB","name":"Installationsschütz 40 A 4S, Spule 230 V","ebene":"E3","src":"Dok 05 §3, 08 §1, 09 §5 (AC1)","te":3,"x_mm":[452.5,505],"tmax_C":55,"verlust":{"p_W":3,"at_A":40,"pole":4,"spule_W":4.5},"iz_A":40},{"bmk":"CU0","article":"KJ100A","maker":"Hager","name":"Verteilerblock 4P (N-GRID)","ebene":"E4","src":"Dok 05 §3, 07 (2 Nm bestätigt 24.08.2026)","te":4,"x_mm":[45,115],"drehmoment_Nm":2},{"bmk":"CU1","article":"KJ100A","maker":"Hager","name":"Verteilerblock 4P (N-LOAD)","ebene":"E4","src":"Dok 05 §3, 07","te":4,"x_mm":[115,185],"drehmoment_Nm":2},{"bmk":"F1","article":"SPE440S","maker":"Hager","name":"Überspannungsableiter Typ 2 4P","ebene":"E4","src":"Dok 05 §3, 07 (3–3,5 Nm)","te":4,"x_mm":[185,255],"drehmoment_Nm":3.5},{"bmk":"F2","article":"NBN350","maker":"Hager","name":"LS B50 3P → Deye GRID","ebene":"E4","src":"Dok 05 §3, 07, 08 §1, 15 §5","te":3,"x_mm":[295,347.5],"tmax_C":60,"verlust":{"p_W":15.4,"at_A":50},"schutz":{"t_s":5,"char":"B","in_A":50},"icn_kA":10,"drehmoment_Nm":2.8},{"bmk":"F5","article":"NCN320","maker":"Hager","name":"LS C20 3P → Wallbox","ebene":"E4","src":"Dok 05 §3, 08 §1, 15 §5","te":3,"x_mm":[356.3,408.8],"tmax_C":60,"verlust":{"p_W":8.04,"at_A":20},"schutz":{"t_s":0.4,"char":"C","in_A":20},"icn_kA":10},{"bmk":"F11","article":"NBN106","maker":"Hager","name":"LS B6 1P → Steuerkreis/T1","ebene":"E4","src":"Dok 05 §3, 08 §1, 15 §5","te":1,"x_mm":[417.5,435],"tmax_C":60,"verlust":{"p_W":1.5,"at_A":6},"schutz":{"t_s":0.4,"char":"B","in_A":6},"icn_kA":10},{"bmk":"F7","article":"DS201 M B16 A30","maker":"ABB","name":"FI/LS B16 30 mA Typ A 1P+N → Heizungspumpe","ebene":"E4","src":"Dok 05 §3, 08 §1, 09 §5 (ABB 2CSC422004B0203), 15 §5","te":2,"x_mm":[435,470],"tmax_C":55,"verlust":{"p_W":5,"at_A":16},"schutz":{"t_s":0.4,"char":"B","in_A":16},"icn_kA":10},{"bmk":"F8.1","article":"CPA640D","maker":"Hager","name":"FI 40 A 300 mA Typ A selektiv 4P vor F8","ebene":"E1","src":"PDS CPA640D 14.09.2026 (datasheets/hager): 4P 40 A, Idn 300 mA, Typ A SEL (selektiv), Inc 10 kA, 40 A bei −25…70 °C, 4,39 W, 4 TE. Ersetzt CDA440D (Entscheidung des Eigentümers 14.09.2026, Variante B, Punkt 27): 30 mA vor 30 mA der Unterverteilung war nicht selektiv, Deye-Handbuch §3.8 verlangt für externe FI ≥ 300 mA, Holzrahmenbau (gebaeude.huelle) → Brandschutz-FI 300 mA; im Inselbetrieb erreicht der Abgangsautomat F8 den Ia nicht (Ik durch den Wechselrichter begrenzt). Platz E1 rechts neben F12 — physische Breite 72 mm, drei Geräte passen nicht in die 210 mm des linken Feldes E0 (auswahl.platziere 14.09.2026); von 12 Anordnungen die mit den wenigsten Wegeverstößen (automatik.layoutPruefen: 82 statt 95).","te":4,"x_mm":[408.8,480.8],"tmax_C":70,"verlust":{"p_W":4.39,"at_A":40},"inc_kA":10},{"bmk":"F9.1","article":"CPA640D","maker":"Hager","name":"FI 40 A 300 mA Typ A selektiv 4P vor F9","ebene":"E0","src":"PDS CPA640D 14.09.2026 (datasheets/hager): 4P 40 A, Idn 300 mA, Typ A SEL (selektiv), Inc 10 kA, 40 A bei −25…70 °C, 4,39 W, 4 TE. Ersetzt CDA440D (Entscheidung des Eigentümers 14.09.2026, Variante B, Punkt 27): 30 mA vor 30 mA der Unterverteilung war nicht selektiv, Deye-Handbuch §3.8 verlangt für externe FI ≥ 300 mA, Holzrahmenbau (gebaeude.huelle) → Brandschutz-FI 300 mA; im Inselbetrieb erreicht der Abgangsautomat F9 den Ia nicht (Ik durch den Wechselrichter begrenzt). Platz E0 links — physische Breite 72 mm, drei Geräte passen nicht in die 210 mm des linken Feldes E0 (auswahl.platziere 14.09.2026); von 12 Anordnungen die mit den wenigsten Wegeverstößen (automatik.layoutPruefen: 82 statt 95).","te":4,"x_mm":[45,117],"tmax_C":70,"verlust":{"p_W":4.39,"at_A":40},"inc_kA":10},{"bmk":"F12.1","article":"CPA640D","maker":"Hager","name":"FI 40 A 300 mA Typ A selektiv 4P vor F12","ebene":"E0","src":"PDS CPA640D 14.09.2026 (datasheets/hager): 4P 40 A, Idn 300 mA, Typ A SEL (selektiv), Inc 10 kA, 40 A bei −25…70 °C, 4,39 W, 4 TE. Ersetzt CDA425D (Entscheidung des Eigentümers 14.09.2026, Variante B, Punkt 27): 30 mA vor 30 mA der Unterverteilung war nicht selektiv, Deye-Handbuch §3.8 verlangt für externe FI ≥ 300 mA, Holzrahmenbau (gebaeude.huelle) → Brandschutz-FI 300 mA; im Inselbetrieb erreicht der Abgangsautomat F12 den Ia nicht (Ik durch den Wechselrichter begrenzt). Platz E0 rechts neben K2…K7 — physische Breite 72 mm, drei Geräte passen nicht in die 210 mm des linken Feldes E0 (auswahl.platziere 14.09.2026); von 12 Anordnungen die mit den wenigsten Wegeverstößen (automatik.layoutPruefen: 82 statt 95).","te":4,"x_mm":[373.8,445.8],"tmax_C":70,"verlust":{"p_W":4.39,"at_A":40},"inc_kA":10}],"leiter":[{"id":"W0a","von":"SLS","nach":"P1","typ":"NYM-J 5×16","s_mm2":16,"l_m":3,"src":"Dok 06 §1; N auf CU0 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","n_von":"CU0"},{"id":"L1","von":"P1","nach":"CU0","typ":"H07V-R 25","s_mm2":25,"l_m":0.45,"src":"Dok 06 §3"},{"id":"L2","von":"CU0","nach":"F2","typ":"H07V-R 16","s_mm2":16,"l_m":0.3,"src":"Dok 06 §3"},{"id":"W1","von":"F2","nach":"Deye.GRID","typ":"NYM-J 5×16","s_mm2":16,"l_m":5,"src":"Dok 06 §1 (Igrid max 32 A; Bypass: Deye-Pfad stromlos, 08 §3); N auf CU0 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":32,"last_bypass_A":0,"quelle_artikel":"SUN-20K-SG05LP3-EU-SM2","n_von":"CU0"},{"id":"L3","von":"CU0","nach":"F5","typ":"H07V-R 6","s_mm2":6,"l_m":0.35,"src":"Dok 06 §3"},{"id":"W8","von":"F5","nach":"Wallbox","typ":"NYM-J 5×4","s_mm2":4,"l_m":12,"src":"Dok 06 §1 (Bypass: Wallbox durch EMS gesperrt, 08 §3); N auf CU0 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":16,"last_bypass_A":0,"quelle_artikel":"KeContact P40","n_von":"CU0"},{"id":"L4","von":"CU0","nach":"HI403R","typ":"H07V-R 25","s_mm2":25,"l_m":0.75,"src":"Dok 06 §3 (im Normalbetrieb stromlos)","betrieb":"bypass"},{"id":"W2","von":"Deye.LOAD","nach":"HI403R","typ":"H07V-R 4×25 + PE 16 (Einzeladern)","s_mm2":25,"l_m":5,"src":"Dok 06 §1; N auf CU1 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","s_pe_mm2":16,"betrieb":"normal","n_von":"CU1"},{"id":"L5","von":"HI403R","nach":"Q1","typ":"H07V-R 25","s_mm2":25,"l_m":0.3,"src":"Dok 06 §3 (Hauptpfad bei InA)","i_A":63},{"id":"L6","von":"Q1","nach":"CU1","typ":"H07V-R 25","s_mm2":25,"l_m":0.4,"src":"Dok 06 §3 (Hauptpfad bei InA)","i_A":63},{"id":"L7","von":"CU1","nach":"F3","typ":"H07V-R 16","s_mm2":16,"l_m":0.45,"src":"Dok 06 §3"},{"id":"L11","von":"F3","nach":"F4","typ":"H07V-R 4","s_mm2":4,"l_m":0.25,"src":"Dok 06 §3"},{"id":"W12","von":"F4","nach":"Wärmepumpe","typ":"NYM-J 5×2.5","s_mm2":2.5,"l_m":9,"src":"Dok 06 §1; N auf N-F3 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":10.7,"n_von":"N-F3"},{"id":"L12","von":"F3","nach":"F6","typ":"H07V-R 6","s_mm2":6,"l_m":0.25,"src":"Dok 06 §3"},{"id":"L13","von":"F6","nach":"K1","typ":"H07V-R 6","s_mm2":6,"l_m":0.25,"src":"Dok 06 §3"},{"id":"W13","von":"K1","nach":"Heizstäbe","typ":"NYM-J 5×4","s_mm2":4,"l_m":7,"src":"Datenblatt CGH-06HR150 (datasheets/sprsun, 13.09.2026): 2 × 3 kW Heizstäbe je zwischen zwei Außenleitern, 7,8 A + 7,8 A; der gemeinsame Außenleiter führt √3 · 7,8 = 13,5 A, die beiden anderen 7,8 A — Modell symmetrisch 3~ mit dem Höchstwert 13,5 A (Entscheidung des Eigentümers 14.09.2026: kein Paketzuschlag, nur das Nötige; Paket v18 rechnete 16,62 A). Paare im Datenblatt nicht benannt. N auf N-F3 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":13.5,"n_von":"N-F3"},{"id":"L8","von":"CU1","nach":"F8.1","typ":"H07V-R 10","s_mm2":10,"l_m":1,"src":"Dok 06 §3"},{"id":"L8b","von":"F8.1","nach":"F8","typ":"H07V-R 10","s_mm2":10,"l_m":0.55,"src":"Dok 06 §3"},{"id":"W9","von":"F8","nach":"UV-Keller","typ":"NYM-J 5×10","s_mm2":10,"l_m":8,"src":"Dok 06 §1; N auf F8.1 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":10,"n_von":"F8.1"},{"id":"L9","von":"CU1","nach":"F9.1","typ":"H07V-R 10","s_mm2":10,"l_m":1,"src":"Dok 06 §3"},{"id":"L9b","von":"F9.1","nach":"F9","typ":"H07V-R 10","s_mm2":10,"l_m":0.45,"src":"Dok 06 §3"},{"id":"W10","von":"F9","nach":"UV-EG","typ":"NYM-J 5×10","s_mm2":10,"l_m":7,"src":"Dok 06 §1; Länge: Bauherr 15.09.2026 — «никак не 10 м, 6–7 максимум», 7 m als obere Grenze angesetzt (Dok 06 hatte 10 m, Trassenaufnahme ausstehend); N auf F9.1 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":10,"n_von":"F9.1"},{"id":"L10","von":"CU1","nach":"F12.1","typ":"H07V-R 6","s_mm2":6,"l_m":1,"src":"Dok 06 §3"},{"id":"L10b","von":"F12.1","nach":"F12","typ":"H07V-R 6","s_mm2":6,"l_m":0.45,"src":"Dok 06 §3"},{"id":"W11","von":"F12","nach":"UV-OG","typ":"NYM-J 5×4","s_mm2":4,"l_m":14,"src":"Dok 06 §1; N auf F12.1 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":7,"n_von":"F12.1"},{"id":"L14","von":"CU1","nach":["F7","F11","F1"],"typ":"H07V-R 4","s_mm2":4,"l_m":0.4,"src":"Dok 06 §3"},{"id":"W14","von":"F7","nach":"Heizungspumpe","typ":"NYM-J 3×1.5","s_mm2":1.5,"l_m":6,"src":"Dok 06 §1; N auf F7 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":2,"phasen":1,"phase":"L1","n_von":"F7"},{"id":"W15","von":"F11","nach":"EMS","typ":"NYM-J 3×1.5 / LiYY 4×0.75","s_mm2":1.5,"l_m":6,"src":"Dok 06 §1; N auf CU1 (DIN VDE 0100-530 §531.2 — Neutralleiter einer RCD-Gruppe getrennt; Auflegepunkt im Paket v18 nicht ausgewiesen)","last_A":1,"phasen":1,"phase":"L1","n_von":"CU1"}],"ort":"Technikraum","etage":"keller","gehaeuse":{"ebenen":[{"id":"E0","y_mm":700},{"id":"E1","y_mm":550,"felder":[{"id":"ganz","x_mm":[47.5,502.5]}]},{"id":"E2","y_mm":400},{"id":"E3","y_mm":250},{"id":"E4","y_mm":100}],"kopf_y_mm":800,"te_mm":17.5,"felder":[{"id":"links","x_mm":[45,255]},{"id":"rechts","x_mm":[295,505]}],"gesperrt":[{"ebene":"E2","feld":"links","grund":"UK21A3 (Q1 auf Adapter, deckt E2 und E3 links)"},{"ebene":"E3","feld":"links","grund":"UK21A3"}],"article":"FP52SN2","maker":"Hager","b_mm":550,"h_mm":800,"t_mm":205,"kanal_tiefe_mm":47.5,"felder_anzahl":2,"reihen_anzahl":5,"in_A":250,"ip":"IP44","ik":"IK09","sk":"II","bausteine":[{"article":"UD12B1","maker":"Hager","name":"Baustein 150 × 500 mm, 2 × 12 PLE","lage":"E0 links+rechts","src":"Systemhandbuch univers N 6LE007035A v13 §4.2.6.1; Entscheidung Punkt 34 (a), 15.09.2026"},{"article":"UD12B2","maker":"Hager","name":"Baustein 150 × 500 mm, 1 × 26 PLE, durchgehender Geräteschlitz","lage":"E1 ganz","src":"Systemhandbuch univers N 6LE007035A v13 §4.2.6.1 (UD..B2: durchgehende Geräteschlitze über die gesamte Bausteinbreite); nötig für HI403R 215 mm — Punkt 34 (a), 15.09.2026"},{"article":"UK21A3","maker":"Hager","name":"Montageplatte 300 × 250 mm für Leistungsschalter x160 (Q1 auf HYA033H)","lage":"E2+E3 links","src":"Paket v18 Dok 05 §1–2; Systemhandbuch §UK21A3"},{"article":"UD21B1","maker":"Hager","name":"Baustein 300 × 250 mm, 2 × 12 PLE","lage":"E2+E3 rechts","src":"Systemhandbuch univers N 6LE007035A v13 §4.2.6.1; Punkt 34 (a), 15.09.2026"},{"article":"UD12B1","maker":"Hager","name":"Baustein 150 × 500 mm, 2 × 12 PLE","lage":"E4 links+rechts","src":"Systemhandbuch univers N 6LE007035A v13 §4.2.6.1; Punkt 34 (a), 15.09.2026"}],"src":"Paket v18 Dok 05 §1–2 (2 Felder × 5 Reihen); PDS FP52SN2: Höhe 800 · Breite 550 · Tiefe 205 mm, IN 250 A. Raster 15.09.2026 (Punkt 34 a): Feldraster 250 mm und Reihenraster 150 mm nach Systemhandbuch univers N 6LE007035A v13 §4.2.6/§4.2.6.1 — Felder 12 PLE = 210 mm mittig im 250-Raster (45–255 / 295–505), Rand 25 mm beidseitig wie in der Breite (25 + 250 + 250 + 25), Reihen 100/250/400/550/700 (HagerCAD-Bildschirmmessung 15.09.2026 bestätigt: Profile 25–47 / 253–273 / 277–295 / 503–525, Schienen auf 100…700, ±1 mm). E1 als UD12B2 mit durchgehendem Geräteschlitz 26 PLE = 455 mm (47,5–502,5) wegen HI403R 215 mm. Verdrahtungsraum: §4.2.6.1 — Abstand Berührungsschutzabdeckung zu Hutschiene 47,5 mm, Randhöhe 46 mm, senkrechte Leitungsführung seitlich je Baustein (UT50C 30 mm zwischen Bausteinen). Vorher: Felder 20–230 / 300–510 und Reihen 105…705 angenommen."},"thermik":{"tamb_C":30,"k":0.665,"c":1.218,"x":0.804,"d":1,"grenze_W":83,"src":"IEC TR 60890 (Gehäuse ohne Lüftungsöffnungen, Tabelle 1: Δt0,5 = k·d·P^x, Δt1,0 = c·Δt0,5; x = 0,804; d = 1, keine waagerechten Trennwände, Tabelle 4). k = 0,665 und c = 1,218 für FP52SN2 (Ae 0,93 m² mit Tiefe bis Frontplatte 143 mm nach Tabelle 3: Deckel 1,4, Front/Seiten 0,9, Rückwand 0,5) abgeleitet aus HagerCAD 7.1.104.0 (Läufe 24.08.2026 bei 83 W: +23/+28 K; 15.09.2026 bei 71 und 75 W: +20/+25, +21/+26 K; Tamb 25 und 30 °C) — Berichte dokumente/hagercad/. Die Kurven des TR (Fig. 7/8, Ausgabe 2022 Tab. 10/11) liegen nicht vor; sobald beschafft, k/c daraus belegen. Profil folgt seither der Verlustleistung des Modells (Dok 08), kein eingefrorener Lauf mehr. Grenze 83 W aus dem Lauf 24.08.2026 (Dok 09 §2, A1)."},"derating":{"NCN":{"in_A":20,"iz_A":{"50":17.81,"55":17.22,"60":16.61},"src":"Hager NCN320 (Dok 09 §4)"},"NBN":{"in_A":50,"iz_A":{"50":43.6,"55":41.85,"60":40.02},"src":"Hager NBN350 (Dok 09 §4)"}},"schienen":[{"id":"PE","art":"pe","name":"PE-Sammelschiene","src":"Regel: jede Schaltgerätekombination führt eine PE-Sammelschiene (DIN EN IEC 61439-1 §8.4.3); im Paket v18 nicht als Position ausgewiesen","y_mm":44},{"id":"N-F3","art":"n","name":"N-Schiene der FI-Gruppe F3","src":"DIN VDE 0100-530 §531.2: Neutralleiter einer RCD-Gruppe getrennt führen; Lage im Paket v18 nicht ausgewiesen","quelle":"F3","y_mm":180,"x_mm":[295,505]}],"betriebsarten":[{"id":"normal","name":"Normalbetrieb","weg":"Deye LOAD → HI403R II → Q1 → CU1","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},{"id":"service_bypass","name":"Service-Bypass","weg":"Netz P1/CU0 → HI403R I → Q1 → CU1 (Wallbox durch das EMS gesperrt)","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},{"id":"trennung","name":"Trennung","weg":"HI403R Stellung 0 — die Kombination ist stromlos","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},{"id":"insel","name":"Inselbetrieb","weg":"Deye LOAD → HI403R II → CU1 ohne Netz; N-PE über das Island-Mode-Relais des Deye","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},{"id":"wallbox","name":"Wallbox","weg":"Netz P1/CU0 → F5, unabhängig; bei Netzausfall spannungslos","src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"}]},{"id":"uv-keller","name":"UV Keller","knoten":[{"id":"SLS","art":"einspeisung","name":"Einspeisung aus UV1 (F8 + F8.1 300 mA S), NYM-J 5x10","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-KF1","art":"verbraucher","name":"Waschmaschine 1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"haushaltsgeraet"},{"id":"V-KF2","art":"verbraucher","name":"Waschtrockner 2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"haushaltsgeraet"},{"id":"V-KF3","art":"verbraucher","name":"Steckdosen Buero/Garage 1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF4","art":"verbraucher","name":"Steckdosen Buero/Garage 2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF5","art":"verbraucher","name":"Steckdosen Buero/Garage 3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF6","art":"verbraucher","name":"Steckdosen Abstell/Garderobe","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF7","art":"verbraucher","name":"Service Technik (Doppelsteckdose)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF8","art":"verbraucher","name":"Licht Keller","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Tastdimmer, dimmbar, N am Dimmer"},{"id":"V-KF9","art":"verbraucher","name":"Licht Garage/Buero","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Praesenzmelder, Treiber 230/24V, Melder schaltet 230V vor Treiber"},{"id":"V-KF10","art":"verbraucher","name":"Fancoils Keller 1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"klima"},{"id":"V-KF11","art":"verbraucher","name":"Fancoils Keller 2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"klima"},{"id":"V-KF12","art":"verbraucher","name":"Kuehlraum (Zukunft)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"kuehlraum"},{"id":"V-KF13","art":"verbraucher","name":"Waschraum nass","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"nass"},{"id":"V-KF14","art":"verbraucher","name":"Bad Keller nass","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"nass"},{"id":"V-KF15","art":"verbraucher","name":"Terrasse Steckdosen IP65","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF16","art":"verbraucher","name":"Terrasse Grill","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-KF17","art":"verbraucher","name":"Terrasse Licht 230V","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht"},{"id":"V-KF18","art":"verbraucher","name":"Aussenlicht Front (Carport+Adresse+Weg)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht"},{"id":"V-KF19","art":"verbraucher","name":"Kellerausgang 1 (Licht+Steckdose)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht"},{"id":"V-KF20","art":"verbraucher","name":"Kellerausgang 2 (Licht+Steckdose)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht"},{"id":"V-KF21","art":"verbraucher","name":"Steckdose Carport IP65 (Hochdruckreiniger)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-KF22","art":"verbraucher","name":"Tuersprech Tor + Briefkasten (Dauerstrom)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steuerung"}],"geraete":[{"bmk":"FI-K1","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — Keller trocken","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[35.5,102.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"FI-K2","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — Terrasse","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[105.5,172.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"FI-K3","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — Aussen/Strasse","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[175.5,242.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"KF1","article":"NBN116","maker":"Hager","name":"Waschmaschine 1","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[35.5,50],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF2","article":"NBN116","maker":"Hager","name":"Waschtrockner 2","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[53,67.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF3","article":"NBN116","maker":"Hager","name":"Steckdosen Buero/Garage 1","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[70.5,85],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF4","article":"NBN116","maker":"Hager","name":"Steckdosen Buero/Garage 2","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[88,102.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF5","article":"NBN116","maker":"Hager","name":"Steckdosen Buero/Garage 3","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[105.5,120],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF6","article":"NBN116","maker":"Hager","name":"Steckdosen Abstell/Garderobe","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[123,137.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF7","article":"NBN116","maker":"Hager","name":"Service Technik (Doppelsteckdose)","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[140.5,155],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF8","article":"NBN113","maker":"Hager","name":"Licht Keller","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[158,172.5],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"KF9","article":"NBN113","maker":"Hager","name":"Licht Garage/Buero","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[175.5,190],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"KF10","article":"DS201 M B10","maker":"ABB","name":"Fancoils Keller 1","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[193,225],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":10},"schutz":{"t_s":5,"char":"B","in_A":10},"icn_kA":10},{"bmk":"KF11","article":"DS201 M B10","maker":"ABB","name":"Fancoils Keller 2","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[35.5,67.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":10},"schutz":{"t_s":5,"char":"B","in_A":10},"icn_kA":10},{"bmk":"KF12","article":"DS201 M B16","maker":"ABB","name":"Kuehlraum (Zukunft)","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[70.5,102.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF13","article":"DS201 M B16","maker":"ABB","name":"Waschraum nass","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[105.5,137.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF14","article":"DS201 M B16","maker":"ABB","name":"Bad Keller nass","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[140.5,172.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF15","article":"NBN116","maker":"Hager","name":"Terrasse Steckdosen IP65","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[175.5,190],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF16","article":"NBN116","maker":"Hager","name":"Terrasse Grill","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[193,207.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF17","article":"NBN116","maker":"Hager","name":"Terrasse Licht 230V","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[210.5,225],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF18","article":"NBN116","maker":"Hager","name":"Aussenlicht Front (Carport+Adresse+Weg)","ebene":"E3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[228,242.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF19","article":"NBN116","maker":"Hager","name":"Kellerausgang 1 (Licht+Steckdose)","ebene":"E4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[35.5,50],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF20","article":"NBN116","maker":"Hager","name":"Kellerausgang 2 (Licht+Steckdose)","ebene":"E4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[53,67.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF21","article":"NBN116","maker":"Hager","name":"Steckdose Carport IP65 (Hochdruckreiniger)","ebene":"E4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[70.5,85],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"KF22","article":"DS201 M B10","maker":"ABB","name":"Tuersprech Tor + Briefkasten (Dauerstrom)","ebene":"E4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[88,120],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":10},"schutz":{"t_s":5,"char":"B","in_A":10},"icn_kA":10},{"bmk":"CU-K","article":"KJ100A","maker":"Hager","name":"Verteilerblock Einspeisung (N je Gruppe getrennt)","ebene":"E4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","te":4,"x_mm":[123,190]}],"leiter":[{"id":"W-uv-keller","von":"SLS","nach":["CU-K"],"typ":"NYM-J 5x10","s_mm2":10,"l_m":8,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Richtung der Zuleitung folgt dem Ort des speisenden Verteilers: liegt er tiefer, kommt das Kabel von unten; liegt er auf derselben Etage, läuft es unter der Decke und kommt von oben. UV1 steht im Keller.","last_A":28.3,"phasen":3,"richtung":"oben","n_von":"CU-K"},{"id":"B-uv-keller-fi","von":"CU-K","nach":["FI-K1"],"typ":"H07V-R 10","s_mm2":10,"l_m":0.8,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — seit 14.09.2026 nur bis FI-K1: FI-K2 und FI-K3 hängen an der Phasenschiene PS-uv-keller-fi","phasen":3},{"id":"PS-uv-keller-fi","von":"FI-K1","nach":["FI-K2","FI-K3"],"typ":"Phasenschiene 4P Gabel 10 mm²","s_mm2":10,"l_m":0.21,"src":"Entscheidung des Eigentümers 14.09.2026: die Verbindung benachbarter Geräte einer Reihe ist eine Phasenschiene, keine Aderleitung — Hager KDN463A, 4P Gabel 10 mm², 63 A, 12 Module (PDS datasheets/hager/KDN463A.pdf, 14.09.2026), auf Länge geschnitten. Sie sitzt an der Einspeiseseite der gespeisten Geräte; drei Aderleitungen mit gleicher Polfolge an beiden Enden hätten sich im Verdrahtungsplan zwangsläufig gekreuzt (REGELN §2, 14.09). Vorher: Teil von B-uv-keller-fi, H07V-R 10, 0,8 m zu drei FI","art":"phasenschiene","article":"KDN463A","maker":"Hager","s_n_mm2":10,"phasen":3},{"id":"R-KF10","von":"CU-K","nach":"KF10","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1"},{"id":"R-KF11","von":"CU-K","nach":"KF11","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L2"},{"id":"R-KF12","von":"CU-K","nach":"KF12","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":10,"phasen":1,"phase":"L1"},{"id":"R-KF13","von":"CU-K","nach":"KF13","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3"},{"id":"R-KF14","von":"CU-K","nach":"KF14","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1"},{"id":"R-KF22","von":"CU-K","nach":"KF22","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1"},{"id":"L01","von":"FI-K1","nach":"KF1","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-K1"},{"id":"WKF1","von":"KF1","nach":"V-KF1","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K1"},{"id":"L02","von":"FI-K1","nach":"KF2","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-K1"},{"id":"WKF2","von":"KF2","nach":"V-KF2","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-K1"},{"id":"L03","von":"FI-K1","nach":"KF3","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-K1"},{"id":"WKF3","von":"KF3","nach":"V-KF3","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":15,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-K1"},{"id":"L04","von":"FI-K1","nach":"KF4","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-K1"},{"id":"WKF4","von":"KF4","nach":"V-KF4","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":15,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K1"},{"id":"L05","von":"FI-K1","nach":"KF5","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-K1"},{"id":"WKF5","von":"KF5","nach":"V-KF5","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":15,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-K1"},{"id":"L06","von":"FI-K1","nach":"KF6","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-K1"},{"id":"WKF6","von":"KF6","nach":"V-KF6","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-K1"},{"id":"L07","von":"FI-K1","nach":"KF7","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-K1"},{"id":"WKF7","von":"KF7","nach":"V-KF7","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K1"},{"id":"L08","von":"FI-K1","nach":"KF8","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"Phase L3 statt L1 (15.09.2026): Phasensymmetrie UV Keller nach Stromkreislasten = In — L1 119 / L2 101 / L3 96 A ergab 23 A über den 20 A aus VDE-AR-N 4100; mit KF8 auf L3: 106 / 101 / 109 A, 8 A. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L3","n_von":"N-FI-K1"},{"id":"WKF8","von":"KF8","nach":"V-KF8","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":12,"src":"Phase L3 statt L1 (15.09.2026): Phasensymmetrie UV Keller nach Stromkreislasten = In — L1 119 / L2 101 / L3 96 A ergab 23 A über den 20 A aus VDE-AR-N 4100; mit KF8 auf L3: 106 / 101 / 109 A, 8 A. Last des Stromkreises = In des Schutzorgans KF8 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L3","richtung":"oben","n_von":"N-FI-K1"},{"id":"L09","von":"FI-K1","nach":"KF9","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","n_von":"N-FI-K1"},{"id":"WKF9","von":"KF9","nach":"V-KF9","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans KF9 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K1"},{"id":"WKF10","von":"KF10","nach":"V-KF10","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1","richtung":"unten","n_von":"KF10"},{"id":"WKF11","von":"KF11","nach":"V-KF11","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L2","richtung":"unten","n_von":"KF11"},{"id":"WKF12","von":"KF12","nach":"V-KF12","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":10,"phasen":1,"phase":"L1","richtung":"unten","n_von":"KF12"},{"id":"WKF13","von":"KF13","nach":"V-KF13","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans KF13 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"KF13"},{"id":"WKF14","von":"KF14","nach":"V-KF14","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans KF14 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"KF14"},{"id":"L10","von":"FI-K2","nach":"KF15","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-K2"},{"id":"WKF15","von":"KF15","nach":"V-KF15","typ":"NYY-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-K2"},{"id":"L11","von":"FI-K2","nach":"KF16","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-K2"},{"id":"WKF16","von":"KF16","nach":"V-KF16","typ":"NYY-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K2"},{"id":"L12","von":"FI-K2","nach":"KF17","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-K2"},{"id":"WKF17","von":"KF17","nach":"V-KF17","typ":"NYY-J 3x1,5","s_mm2":1.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans KF17 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-K2"},{"id":"L13","von":"FI-K3","nach":"KF18","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-K3"},{"id":"WKF18","von":"KF18","nach":"V-KF18","typ":"NYY-J 3x1,5","s_mm2":1.5,"l_m":18,"src":"Last des Stromkreises = In des Schutzorgans KF18 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-K3"},{"id":"L14","von":"FI-K3","nach":"KF19","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-K3"},{"id":"WKF19","von":"KF19","nach":"V-KF19","typ":"NYY-J 5x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-K3"},{"id":"L15","von":"FI-K3","nach":"KF20","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-K3"},{"id":"WKF20","von":"KF20","nach":"V-KF20","typ":"NYY-J 5x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-K3"},{"id":"L16","von":"FI-K3","nach":"KF21","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-K3"},{"id":"WKF21","von":"KF21","nach":"V-KF21","typ":"NYY-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-K3"},{"id":"WKF22","von":"KF22","nach":"V-KF22","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1","richtung":"unten","n_von":"KF22"}],"ort":"Keller","etage":"keller","gehaeuse":{"ebenen":[{"id":"E0","y_mm":625},{"id":"E1","y_mm":500},{"id":"E2","y_mm":375},{"id":"E3","y_mm":250},{"id":"E4","y_mm":125}],"kopf_y_mm":750,"te_mm":17.5,"felder":[{"id":"feld","x_mm":[34,244]}],"gesperrt":[],"article":"VA60CN","maker":"Hager","b_mm":278,"h_mm":750,"t_mm":96.5,"kanal_tiefe_mm":70,"reihen_anzahl":5,"in_A":63,"ip":"IP30","sk":"II","src":"Hager volta VA60CN: PDS VA60CN_0101_de-DE (datasheets/hager, 22.09.2026): «Kleinv.,volta,APV,5x12PLE,IP30, ohne Tür», Höhe 765 mm, Breite 305 mm, Tiefe 96,50 mm, Anzahl Reihen 5, Anzahl Module 60, Bemessungsstrom IN 63 A, Maximale Verlustleistung pro Schrank bei ΔT=20K 43,6 W, Schutzklasse II, Schutzart IP30. Ersetzt VA48CN nach PLANER-REGELN §10 (G3: 44 von 48 TE belegt, 0 % statt der geforderten 20 % Reserve; G4: 25,27 W über dem Herstellerpunkt 20,5 W). Reihenabstand 125 mm nach DIN 43871 wie beim VA48CN; die fünfte Reihe kommt oben hinzu, die Geräte bleiben auf ihrer Höhe — die Reihennamen wandern um eins nach unten (altes E0 = neues E1). Einbaubreite 278 mm und Geräteeinbautiefe 70 mm unverändert (Bestellhilfe volta 24DE0047). IP30 statt der bisher im Modell stehenden IP40: das PDS nennt IP30, der Widerspruch war ein Übernahmefehler aus Paket v18 (gefunden vom Konzierge 22.09.2026)."},"thermik":{"tamb_C":20,"k":0.9614,"c":1.218,"x":0.804,"d":1,"rdf":0.5,"grenze_W":43.6,"src":"IEC TR 60890, Tabelle 1 (Gehäuse ohne Lüftungsöffnungen, x = 0,804; d = 1). k = 20 K / 20.5 W^0,804 = 1.7635: aus dem PDS VA48CN «Maximale Verlustleistung pro Schrank bei ΔT = 20 K: 20.5 W» (datasheets/hager/VA48CN.pdf) — der Herstellerpunkt der Kurve; c = 1,218 ANGENOMMEN (Wert des FP52SN2 aus HagerCAD; volta-Wert offen — Kalibrierung oder TR 60890:2022 Tab. 11). RDF 0.5: DIN EN IEC 61439-3 Tabelle 101 nach Zahl der Abgänge (22 Hauptstromkreise; Werte 2–3: 0,8, 4–5: 0,7, 6–9: 0,6, ≥ 10: 0,5 — Norm nicht auf Datei, Tabelle nach Hensel-Leitfaden 61439 Schritt 2 / mennekes.de; Methode Pv · RDF²: ABB Technik-Talk «Wärmeberechnung nach EN 61439», Folie 12). grenze_W = 20.5 W = Verlustleistung, bei der der Hersteller 20 K ausweist. Vorher: +20/+25 K angenommen, kein Nachweis. — Tamb 20 °C: Raumtemperatur am Aufstellort (Keller), Angabe des Eigentümers 15.09.2026 (vorher 30 °C ohne Quelle). RDF wirkt seit 15.09.2026 auf die Ströme der Abgänge (PLANER-REGELN §9 E1–E6), nicht als RDF² über der Summe; grenze_W bleibt der Herstellerpunkt."},"derating":{"NBN116":{"in_A":16,"iz_A":{"30":16,"40":15.04,"50":14.02,"55":13.48,"60":12.91,"65":12.32,"70":11.7},"src":"PDS NBN116_0101_de-DE, Nennstrom bei Temperatur (15.09.2026)"},"NBN113":{"in_A":13,"iz_A":{"30":13,"40":12.2,"50":11.35,"55":10.9,"60":10.42,"65":9.93,"70":9.41},"src":"PDS NBN113_3301_pl-PL, Prąd znamionowy w temperaturze (15.09.2026)"}},"schienen":[{"id":"PE","art":"pe","name":"PE-Schiene","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","y_mm":40},{"id":"N-FI-K1","art":"n","name":"N-Schiene FI-K1","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-K1","y_mm":60},{"id":"N-FI-K2","art":"n","name":"N-Schiene FI-K2","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-K2","y_mm":60},{"id":"N-FI-K3","art":"n","name":"N-Schiene FI-K3","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-K3","y_mm":60}]},{"id":"uv-eg","name":"UV Erdgeschoss","knoten":[{"id":"SLS","art":"einspeisung","name":"Einspeisung aus UV1 (F9 + F9.1 300 mA S), NYM-J 5x10","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-EF1","art":"verbraucher","name":"Kochfeld Induktion 8,2 kW","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"kochen"},{"id":"V-EF2","art":"verbraucher","name":"Dampf-/Backofen","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"backofen"},{"id":"V-EF3","art":"verbraucher","name":"Mikrowelle+Grill","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-EF4","art":"verbraucher","name":"Geschirrspueler","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"haushaltsgeraet"},{"id":"V-EF5","art":"verbraucher","name":"Kaffee+Haube","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-EF6","art":"verbraucher","name":"Kuehlgeraete x3","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"kuehlen"},{"id":"V-EF7","art":"verbraucher","name":"Steckdosen-Track Wohn-Kueche","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-EF8","art":"verbraucher","name":"Steckdosen-Track Schlafzimmer 1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-EF9","art":"verbraucher","name":"Steckdosen-Track Schlafzimmer 2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-EF10","art":"verbraucher","name":"Licht A EG","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Tastdimmer, dimmbar, N am Dimmer"},{"id":"V-EF11","art":"verbraucher","name":"Licht B EG","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Praesenzmelder, Treiber 230/24V, Melder schaltet 230V vor Treiber"},{"id":"V-EF12","art":"verbraucher","name":"Fancoils EG (Schleife)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"klima"},{"id":"V-EF13","art":"verbraucher","name":"Bad 1 nass","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"nass"},{"id":"V-EF14","art":"verbraucher","name":"Bad 2 nass","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"nass"}],"geraete":[{"bmk":"EF0","article":"SBN440","maker":"Hager","name":"Etagen-Hauptschalter 40A 4p","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS SBN440_0101_de-DE (15.09.2026): Betriebstemperatur −20…70 °C; Verlustleistung 1,10 W je Pol bei 40 A: PDS SBN440 (15.09.2026)","te":4,"x_mm":[35.5,102.5],"tmax_C":70,"verlust":{"p_W":4.4,"at_A":40,"pole":4}},{"bmk":"FI-E1","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — Kueche stark","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[105.5,172.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"FI-E2","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — Steckdosen + Licht","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[175.5,242.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"EF1","article":"NCN316","maker":"Hager","name":"Kochfeld Induktion 8,2 kW","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NCN316_0101_de-DE: Betriebstemperatur −25…70 °C; Verlustleistung 8,27 W bei IN (3 Pole): PDS NCN316 und BMEcat EF005387 — wie F4 in UV1; vorher 2,5 W angenommen","te":3,"x_mm":[35.5,85],"tmax_C":70,"verlust":{"p_W":8.27,"at_A":16},"schutz":{"t_s":5,"char":"C","in_A":16},"icn_kA":10},{"bmk":"EF2","article":"NBN116","maker":"Hager","name":"Dampf-/Backofen","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[88,102.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF3","article":"NBN116","maker":"Hager","name":"Mikrowelle+Grill","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[105.5,120],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF4","article":"NBN116","maker":"Hager","name":"Geschirrspueler","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[123,137.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF5","article":"NBN116","maker":"Hager","name":"Kaffee+Haube","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[140.5,155],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF6","article":"DS201 M B16","maker":"ABB","name":"Kuehlgeraete x3","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[158,190],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF7","article":"NBN116","maker":"Hager","name":"Steckdosen-Track Wohn-Kueche","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[193,207.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF8","article":"NBN116","maker":"Hager","name":"Steckdosen-Track Schlafzimmer 1","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[210.5,225],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF9","article":"NBN116","maker":"Hager","name":"Steckdosen-Track Schlafzimmer 2","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[228,242.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF10","article":"NBN113","maker":"Hager","name":"Licht A EG","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[35.5,50],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"EF11","article":"NBN113","maker":"Hager","name":"Licht B EG","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[53,67.5],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"EF12","article":"DS201 M B10","maker":"ABB","name":"Fancoils EG (Schleife)","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[70.5,102.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":10},"schutz":{"t_s":5,"char":"B","in_A":10},"icn_kA":10},{"bmk":"EF13","article":"DS201 M B16","maker":"ABB","name":"Bad 1 nass","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[105.5,137.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"EF14","article":"DS201 M B16","maker":"ABB","name":"Bad 2 nass","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[140.5,172.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"CU-E","article":"KJ100A","maker":"Hager","name":"Verteilerblock Einspeisung (N je Gruppe getrennt)","ebene":"E2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","te":4,"x_mm":[175.5,242.5]}],"leiter":[{"id":"W-uv-eg","von":"SLS","nach":["CU-E"],"typ":"NYM-J 5x10","s_mm2":10,"l_m":7,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Länge wie uv1/W10: Bauherr 15.09.2026 «6–7 m максимум», 7 m als obere Grenze; Richtung der Zuleitung folgt dem Ort des speisenden Verteilers: liegt er tiefer, kommt das Kabel von unten; liegt er auf derselben Etage, läuft es unter der Decke und kommt von oben. UV1 steht im Keller.","last_A":28.3,"phasen":3,"richtung":"unten","n_von":"CU-E"},{"id":"B-uv-eg","von":"CU-E","nach":["EF0"],"typ":"H07V-R 10","s_mm2":10,"l_m":0.8,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","phasen":3},{"id":"B-uv-eg-fi","von":"EF0","nach":["FI-E1","FI-E2"],"typ":"Phasenschiene 4P Gabel 10 mm²","s_mm2":10,"l_m":0.21,"src":"Entscheidung des Eigentümers 14.09.2026: die Verbindung benachbarter Geräte einer Reihe ist eine Phasenschiene, keine Aderleitung — Hager KDN463A, 4P Gabel 10 mm², 63 A, 12 Module (PDS datasheets/hager/KDN463A.pdf, 14.09.2026), auf Länge geschnitten. Sie sitzt an der Einspeiseseite der gespeisten Geräte; drei Aderleitungen mit gleicher Polfolge an beiden Enden hätten sich im Verdrahtungsplan zwangsläufig gekreuzt (REGELN §2, 14.09). Vorher: H07V-R 10, 0.8 m (v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUE…)","art":"phasenschiene","article":"KDN463A","maker":"Hager","s_n_mm2":10,"phasen":3},{"id":"R-EF6","von":"EF0","nach":"EF6","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":10,"phasen":1,"phase":"L2"},{"id":"R-EF12","von":"EF0","nach":"EF12","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L3"},{"id":"R-EF13","von":"EF0","nach":"EF13","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2"},{"id":"R-EF14","von":"EF0","nach":"EF14","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3"},{"id":"L01","von":"FI-E1","nach":"EF1","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":3,"n_von":"N-FI-E1"},{"id":"WEF1","von":"EF1","nach":"V-EF1","typ":"NYM-J 5x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":3,"richtung":"unten","n_von":"N-FI-E1"},{"id":"L02","von":"FI-E1","nach":"EF2","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-E1"},{"id":"WEF2","von":"EF2","nach":"V-EF2","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-E1"},{"id":"L03","von":"FI-E1","nach":"EF3","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-E1"},{"id":"WEF3","von":"EF3","nach":"V-EF3","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-E1"},{"id":"L04","von":"FI-E1","nach":"EF4","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-E1"},{"id":"WEF4","von":"EF4","nach":"V-EF4","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-E1"},{"id":"L05","von":"FI-E1","nach":"EF5","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-E1"},{"id":"WEF5","von":"EF5","nach":"V-EF5","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":10,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-E1"},{"id":"WEF6","von":"EF6","nach":"V-EF6","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":10,"phasen":1,"phase":"L2","richtung":"unten","n_von":"EF6"},{"id":"L06","von":"FI-E2","nach":"EF7","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-E2"},{"id":"WEF7","von":"EF7","nach":"V-EF7","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-E2"},{"id":"L07","von":"FI-E2","nach":"EF8","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-E2"},{"id":"WEF8","von":"EF8","nach":"V-EF8","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-E2"},{"id":"L08","von":"FI-E2","nach":"EF9","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","n_von":"N-FI-E2"},{"id":"WEF9","von":"EF9","nach":"V-EF9","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"N-FI-E2"},{"id":"L09","von":"FI-E2","nach":"EF10","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L1","n_von":"N-FI-E2"},{"id":"WEF10","von":"EF10","nach":"V-EF10","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":14,"src":"Last des Stromkreises = In des Schutzorgans EF10 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L1","richtung":"oben","n_von":"N-FI-E2"},{"id":"L10","von":"FI-E2","nach":"EF11","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","n_von":"N-FI-E2"},{"id":"WEF11","von":"EF11","nach":"V-EF11","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":14,"src":"Last des Stromkreises = In des Schutzorgans EF11 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-E2"},{"id":"WEF12","von":"EF12","nach":"V-EF12","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L3","richtung":"unten","n_von":"EF12"},{"id":"WEF13","von":"EF13","nach":"V-EF13","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans EF13 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"EF13"},{"id":"WEF14","von":"EF14","nach":"V-EF14","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans EF14 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"EF14"}],"ort":"Erdgeschoss","etage":"eg","gehaeuse":{"ebenen":[{"id":"E0","y_mm":432.5},{"id":"E1","y_mm":307.5},{"id":"E2","y_mm":182.5}],"kopf_y_mm":615,"te_mm":17.5,"felder":[{"id":"feld","x_mm":[34,244]}],"gesperrt":[],"article":"VU36NC","maker":"Hager","b_mm":278,"h_mm":615,"t_mm":94.5,"kanal_tiefe_mm":70,"reihen_anzahl":3,"in_A":63,"ip":"IP40","sk":"II","src":"Hager volta VU36NC: PDS VU36NC_0101_de-DE (datasheets/hager, 14.09.2026) und Bestellhilfe volta 24DE0047 (Feb 2024): H 630.5 × B 348 × T 94.5 mm, 3 Reihen à 12 PLE; Reihenabstand 125 mm nach DIN 43871 (Höhenreihe 356/505,5/630,5/755,5 mm der UP-Baugröße); Modellkoordinaten = lichter Innenraum: Breite 278 mm = 12 PLE (210) + 2 × 34 mm seitlicher Verdrahtungskanal (Hager Technik-Übersicht volta|vector 20DE0001: 34 mm je Seite, 10 mm unter der Hutschiene — Fundstelle über Suchauszug, Original bei Hager nachzuprüfen), lichte Höhe 615.0 mm (Einbauhöhe 615 mm), Reihen mittig; nutzbare Kanaltiefe = Geräteeinbautiefe max. 70 mm. Vorher: Maße angenommen (b 252, Reihenabstand 90)."},"thermik":{"tamb_C":25,"k":1.6363,"c":1.218,"x":0.804,"d":1,"rdf":0.5,"grenze_W":22.5,"src":"IEC TR 60890, Tabelle 1 (Gehäuse ohne Lüftungsöffnungen, x = 0,804; d = 1). k = 20 K / 22.5 W^0,804 = 1.6363: aus dem PDS VU36NC «Maximale Verlustleistung pro Schrank bei ΔT = 20 K: 22.5 W» (datasheets/hager/VU36NC.pdf) — der Herstellerpunkt der Kurve; c = 1,218 ANGENOMMEN (Wert des FP52SN2 aus HagerCAD; volta-Wert offen — Kalibrierung oder TR 60890:2022 Tab. 11). RDF 0.5: DIN EN IEC 61439-3 Tabelle 101 nach Zahl der Abgänge (14 Hauptstromkreise; Werte 2–3: 0,8, 4–5: 0,7, 6–9: 0,6, ≥ 10: 0,5 — Norm nicht auf Datei, Tabelle nach Hensel-Leitfaden 61439 Schritt 2 / mennekes.de; Methode Pv · RDF²: ABB Technik-Talk «Wärmeberechnung nach EN 61439», Folie 12). grenze_W = 22.5 W = Verlustleistung, bei der der Hersteller 20 K ausweist. Vorher: +20/+25 K angenommen, kein Nachweis. — Tamb 25 °C: Raumtemperatur am Aufstellort (Flur EG), Angabe des Eigentümers 15.09.2026 (vorher 30 °C ohne Quelle). RDF wirkt seit 15.09.2026 auf die Ströme der Abgänge (PLANER-REGELN §9 E1–E6), nicht als RDF² über der Summe; grenze_W bleibt der Herstellerpunkt."},"derating":{"NCN316":{"in_A":16,"iz_A":{"30":16,"40":14.94,"50":13.8,"55":13.19,"60":12.56,"65":11.89,"70":11.18},"src":"PDS NCN316_0101_de-DE, Nennstrom bei Temperatur"},"NBN116":{"in_A":16,"iz_A":{"30":16,"40":15.04,"50":14.02,"55":13.48,"60":12.91,"65":12.32,"70":11.7},"src":"PDS NBN116_0101_de-DE, Nennstrom bei Temperatur (15.09.2026)"},"NBN113":{"in_A":13,"iz_A":{"30":13,"40":12.2,"50":11.35,"55":10.9,"60":10.42,"65":9.93,"70":9.41},"src":"PDS NBN113_3301_pl-PL, Prąd znamionowy w temperaturze (15.09.2026)"}},"schienen":[{"id":"PE","art":"pe","name":"PE-Schiene","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","y_mm":40},{"id":"N-FI-E1","art":"n","name":"N-Schiene FI-E1","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-E1","y_mm":595},{"id":"N-FI-E2","art":"n","name":"N-Schiene FI-E2","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-E2","y_mm":595}]},{"id":"uv-og","name":"UV Obergeschoss","knoten":[{"id":"SLS","art":"einspeisung","name":"Einspeisung aus UV1 (F12 + F12.1 300 mA S), NYM-J 5x4","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend"},{"id":"V-OF1","art":"verbraucher","name":"Steckdosen-Track Schlafzimmer 1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-OF2","art":"verbraucher","name":"Steckdosen-Track Schlafzimmer 2","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"steckdosen"},{"id":"V-OF3","art":"verbraucher","name":"Licht A OG","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Tastdimmer, dimmbar, N am Dimmer"},{"id":"V-OF4","art":"verbraucher","name":"Licht B OG","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"licht","steuerung":"Praesenzmelder, Treiber 230/24V, Melder schaltet 230V vor Treiber"},{"id":"V-OF5","art":"verbraucher","name":"Fancoils OG (Schleife)","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"klima"},{"id":"V-OF6","art":"verbraucher","name":"Bad OG nass","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","klasse":"nass"}],"geraete":[{"bmk":"OF0","article":"SBN440","maker":"Hager","name":"Etagen-Hauptschalter 40A 4p","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS SBN440_0101_de-DE (15.09.2026): Betriebstemperatur −20…70 °C; Verlustleistung 1,10 W je Pol bei 40 A: PDS SBN440 (15.09.2026)","te":4,"x_mm":[35.5,102.5],"tmax_C":70,"verlust":{"p_W":4.4,"at_A":40,"pole":4}},{"bmk":"FI-O1","article":"CDA440D","maker":"Hager","name":"FI Typ A 4p 30mA — trocken (Schlafzimmer, Licht)","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS CDA440D_0101_de-DE (02.09.2026): Betriebstemperatur −25…40 °C — wie Punkt 27 in UV1 — 15.09.2026 (PLANER-REGELN §9 E4, Eigentümer): «Leistungsabgabe bei IN 6,50 W» ist Verlust bei 40 A, quadratisch mit dem Strom, kein Festverlust; Tmax 70 °C nach der Nennstromtabelle des PDS (40 A bei 45…70 °C) — die Zeile «Betriebstemperatur −25…40 °C» desselben PDS widerspricht ihr, Entscheidung Eigentümer 15.09.2026: Tabelle gilt (ABWEICHUNGEN §G)","te":4,"x_mm":[105.5,172.5],"tmax_C":70,"verlust":{"p_W":6.5,"at_A":40},"inc_kA":6},{"bmk":"OF1","article":"NBN116","maker":"Hager","name":"Steckdosen-Track Schlafzimmer 1","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[175.5,190],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"OF2","article":"NBN116","maker":"Hager","name":"Steckdosen-Track Schlafzimmer 2","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN116_0101_de-DE (15.09.2026): Betriebstemperatur −25…70 °C; Verlustleistung 2,62 W bei IN: Hager BMEcat ETIM10 2026-06 (Katalog Hager-8780, EF005387); vorher 2,5 W angenommen","te":1,"x_mm":[193,207.5],"tmax_C":70,"verlust":{"p_W":2.62,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"OF3","article":"NBN113","maker":"Hager","name":"Licht A OG","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[210.5,225],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"OF4","article":"NBN113","maker":"Hager","name":"Licht B OG","ebene":"E0","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: PDS NBN113_3301_pl-PL (15.09.2026): Zakres temperatur pracy −25…70 °C; Verlustleistung 2,31 W bei IN: Hager BMEcat ETIM10 2026-06 (EF005387); vorher 2 W angenommen","te":1,"x_mm":[228,242.5],"tmax_C":70,"verlust":{"p_W":2.31,"at_A":13},"schutz":{"t_s":5,"char":"B","in_A":13},"icn_kA":10},{"bmk":"OF5","article":"DS201 M B10","maker":"ABB","name":"Fancoils OG (Schleife)","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[35.5,67.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":10},"schutz":{"t_s":5,"char":"B","in_A":10},"icn_kA":10},{"bmk":"OF6","article":"DS201 M B16","maker":"ABB","name":"Bad OG nass","ebene":"E1","src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend — Tmax/Verlust 15.09.2026: ABB Katalog 2CSC422004B0203: Ambient temperature −25…+55 °C (wie F7 in UV1) — 15.09.2026 (§9 E4): 3,4 W ist der Datenblattwert bei In (ABWEICHUNGEN §C, F7), quadratisch mit dem Strom; für B10 derselbe Wert wie B16 angenommen (ABB nennt je Bemessungsstrom keinen eigenen)","te":2,"x_mm":[70.5,102.5],"tmax_C":55,"verlust":{"p_W":3.4,"at_A":16},"schutz":{"t_s":5,"char":"B","in_A":16},"icn_kA":10},{"bmk":"F-O1","article":"SPE440S","maker":"Hager","name":"Überspannungsableiter Typ 2 4P — Schutzstufe UV OG (W11 14 m > 10 m)","ebene":"E1","src":"Entscheidung des Eigentümers 15.09.2026 (Punkt 25): W11 zu UV OG ist 14 m — über 10 m verlangt Hager Tipp 41 (25DE0139, S. «korrekt installieren») eine weitere Schutzstufe in der Unterverteilung; Tipp 41 nennt SPE440S als Typ-2-Beispiel für die UV, Up 1,35 kV < 1,5 kV deckt den Endgeräteschutz (Typ-3-Wirkung, Kategorie II). Werte PDS datasheets/hager/SPE440S.pdf (Betriebstemperatur −40…85 °C, Drehmoment 3–3,5 Nm, 4 Module). Platz: E1 rechts neben OF6 (OF5+OF6 = 4 TE, 8 TE frei), einspeiseseitig vor FI-O1.","te":4,"x_mm":[105.5,175.5],"tmax_C":85,"drehmoment_Nm":3.5}],"leiter":[{"id":"W-uv-og","von":"SLS","nach":["OF0"],"typ":"NYM-J 5x4","s_mm2":4,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Richtung der Zuleitung folgt dem Ort des speisenden Verteilers: liegt er tiefer, kommt das Kabel von unten; liegt er auf derselben Etage, läuft es unter der Decke und kommt von oben. UV1 steht im Keller.","last_A":22.1,"phasen":3,"richtung":"unten","n_von":"FI-O1"},{"id":"B-uv-og-fi","von":"OF0","nach":["FI-O1"],"typ":"Phasenschiene 4P Gabel 10 mm²","s_mm2":10,"l_m":0.14,"src":"Entscheidung des Eigentümers 14.09.2026: die Verbindung benachbarter Geräte einer Reihe ist eine Phasenschiene, keine Aderleitung — Hager KDN463A, 4P Gabel 10 mm², 63 A, 12 Module (PDS datasheets/hager/KDN463A.pdf, 14.09.2026), auf Länge geschnitten. Sie sitzt an der Einspeiseseite der gespeisten Geräte; drei Aderleitungen mit gleicher Polfolge an beiden Enden hätten sich im Verdrahtungsplan zwangsläufig gekreuzt (REGELN §2, 14.09). Vorher: H07V-R 4, 0.8 m (v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUE…)","art":"phasenschiene","article":"KDN463A","maker":"Hager","s_n_mm2":10,"phasen":3},{"id":"R-OF5","von":"OF0","nach":"OF5","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1"},{"id":"R-OF6","von":"OF0","nach":"OF6","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3"},{"id":"L01","von":"FI-O1","nach":"OF1","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","n_von":"N-FI-O1"},{"id":"WOF1","von":"OF1","nach":"V-OF1","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L1","richtung":"unten","n_von":"N-FI-O1"},{"id":"L02","von":"FI-O1","nach":"OF2","typ":"H07V-R 2,5","s_mm2":2.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","n_von":"N-FI-O1"},{"id":"WOF2","von":"OF2","nach":"V-OF2","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":14,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-O1"},{"id":"L03","von":"FI-O1","nach":"OF3","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"Phase L3 statt L1 (15.09.2026): Phasensymmetrie UV OG — L1 34 / L2 26 / L3 10 A ergab 24 A Schieflast über den 20 A aus VDE-AR-N 4100; mit OF3 auf L3: 24 / 26 / 20 A, 6 A. Übrige Werte: v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L3","n_von":"N-FI-O1"},{"id":"WOF3","von":"OF3","nach":"V-OF3","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":14,"src":"Last des Stromkreises = In des Schutzorgans OF3 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. Phase L3 statt L1 (15.09.2026): Phasensymmetrie UV OG — L1 34 / L2 26 / L3 10 A ergab 24 A Schieflast über den 20 A aus VDE-AR-N 4100; mit OF3 auf L3: 24 / 26 / 20 A, 6 A. Übrige Werte: v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L3","richtung":"oben","n_von":"N-FI-O1"},{"id":"L04","von":"FI-O1","nach":"OF4","typ":"H07V-R 2,5","s_mm2":1.5,"l_m":0.6,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","n_von":"N-FI-O1"},{"id":"WOF4","von":"OF4","nach":"V-OF4","typ":"NYM-J 3x1,5","s_mm2":1.5,"l_m":14,"src":"Last des Stromkreises = In des Schutzorgans OF4 (13 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":13,"phasen":1,"phase":"L2","richtung":"unten","n_von":"N-FI-O1"},{"id":"WOF5","von":"OF5","nach":"V-OF5","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":8,"phasen":1,"phase":"L1","richtung":"oben","n_von":"OF5"},{"id":"WOF6","von":"OF6","nach":"V-OF6","typ":"NYM-J 3x2,5","s_mm2":2.5,"l_m":12,"src":"Last des Stromkreises = In des Schutzorgans OF6 (16 A), DIN VDE 0100-430 — 15.09.2026; vorher 10 A angenommen. v19 rebuild auf v18-Konventionen (Kirschstr41_UV1_v18_AUSFUEHRUNGSPAKET); Masse/Längen angenommen — Erwärmungsnachweis und Trassenaufnahme ausstehend","last_A":16,"phasen":1,"phase":"L3","richtung":"unten","n_von":"OF6"},{"id":"R-F-O1","von":"OF0","nach":"F-O1","typ":"H07V-K 6","s_mm2":6,"l_m":0.4,"src":"Stichverdrahtung ab den Abgangsklemmen des Hauptschalters OF0 (vor FI-O1: DIN VDE 0100-534, SPD vor dem RCD), L1/L2/L3/N zum Ableiter, PE zur PE-Schiene; Hager Tipp 41: Typ 2 mind. 2,5 mm² an den Außenleitern, 6 mm² zum PE, gesamte Strecke a+b+c ≤ 0,5 m — hier 0,4 m Aderleitung + PE-Anschluss; ohne eigene Vorsicherung (SPE440S: Stich bis 315 A, davor F12 B25). Gabelphasenschiene KDN463A an OF0 lässt einen zweiten Leiter in der Klemme zu — bei der Aufnahme bestätigen. Kein Laststrom.","s_n_mm2":6,"s_pe_mm2":6,"last_A":0,"phasen":3}],"ort":"Obergeschoss","etage":"og","gehaeuse":{"ebenen":[{"id":"E0","y_mm":240},{"id":"E1","y_mm":115}],"kopf_y_mm":355,"te_mm":17.5,"felder":[{"id":"feld","x_mm":[34,244]}],"gesperrt":[],"article":"VA24CN","maker":"Hager","b_mm":278,"h_mm":355,"t_mm":96.5,"kanal_tiefe_mm":70,"reihen_anzahl":2,"in_A":63,"ip":"IP40","sk":"II","src":"Hager volta VA24CN: PDS VA24CN_0101_de-DE (datasheets/hager, 14.09.2026) und Bestellhilfe volta 24DE0047 (Feb 2024): H 370 × B 305 × T 96.5 mm, 2 Reihen à 12 PLE; Reihenabstand 125 mm nach DIN 43871 (Höhenreihe 356/505,5/630,5/755,5 mm der UP-Baugröße); Modellkoordinaten = lichter Innenraum: Breite 278 mm = 12 PLE (210) + 2 × 34 mm seitlicher Verdrahtungskanal (Hager Technik-Übersicht volta|vector 20DE0001: 34 mm je Seite, 10 mm unter der Hutschiene — Fundstelle über Suchauszug, Original bei Hager nachzuprüfen), lichte Höhe 355.0 mm (Außenmaß 370 mm), Reihen mittig; nutzbare Kanaltiefe = Geräteeinbautiefe max. 70 mm. Vorher: Maße angenommen (b 252, Reihenabstand 90)."},"thermik":{"tamb_C":25,"k":2.267,"c":1.218,"x":0.804,"d":1,"rdf":0.6,"grenze_W":15,"src":"IEC TR 60890, Tabelle 1 (Gehäuse ohne Lüftungsöffnungen, x = 0,804; d = 1). k = 20 K / 15.0 W^0,804 = 2.267: aus dem PDS VA24CN «Maximale Verlustleistung pro Schrank bei ΔT = 20 K: 15.0 W» (datasheets/hager/VA24CN.pdf) — der Herstellerpunkt der Kurve; c = 1,218 ANGENOMMEN (Wert des FP52SN2 aus HagerCAD; volta-Wert offen — Kalibrierung oder TR 60890:2022 Tab. 11). RDF 0.6: DIN EN IEC 61439-3 Tabelle 101 nach Zahl der Abgänge (6 Hauptstromkreise; Werte 2–3: 0,8, 4–5: 0,7, 6–9: 0,6, ≥ 10: 0,5 — Norm nicht auf Datei, Tabelle nach Hensel-Leitfaden 61439 Schritt 2 / mennekes.de; Methode Pv · RDF²: ABB Technik-Talk «Wärmeberechnung nach EN 61439», Folie 12). grenze_W = 15.0 W = Verlustleistung, bei der der Hersteller 20 K ausweist. Vorher: +20/+25 K angenommen, kein Nachweis. — Tamb 25 °C: Raumtemperatur am Aufstellort (Flur OG), Angabe des Eigentümers 15.09.2026 (vorher 30 °C ohne Quelle). RDF wirkt seit 15.09.2026 auf die Ströme der Abgänge (PLANER-REGELN §9 E1–E6), nicht als RDF² über der Summe; grenze_W bleibt der Herstellerpunkt."},"derating":{"NBN116":{"in_A":16,"iz_A":{"30":16,"40":15.04,"50":14.02,"55":13.48,"60":12.91,"65":12.32,"70":11.7},"src":"PDS NBN116_0101_de-DE, Nennstrom bei Temperatur (15.09.2026)"},"NBN113":{"in_A":13,"iz_A":{"30":13,"40":12.2,"50":11.35,"55":10.9,"60":10.42,"65":9.93,"70":9.41},"src":"PDS NBN113_3301_pl-PL, Prąd znamionowy w temperaturze (15.09.2026)"}},"schienen":[{"id":"PE","art":"pe","name":"PE-Schiene","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","y_mm":40},{"id":"N-FI-O1","art":"n","name":"N-Schiene FI-O1","src":"N-Schiene gegenüber der Kabeleinführung, PE auf der Seite, an der die meisten Kabel den Schrank verlassen. So teilen sich Blau und Grün keinen Weg, und der dicke Zuleiter drängt sich nicht mit dem N-Block. Lage im Gehäuse bei der Aufnahme zu bestätigen.","quelle":"FI-O1","y_mm":335}]}],"konstanten":{"rho_verlust":0.0199,"rho_kurzschluss":0.0225,"c_min":0.95,"pe_intern_mm2":16,"src":"Dok 06 §2 (ρ 0,0199), 15 §3 (ρ 0,0225, c 0,95), 02 (PE1 = KM13A 16 mm²)"},"steuerung":{"netzbetreiber":"Steuerbox Stromnetz Berlin auf Deye-DI (§14a) sowie NA-Schutz, Wärmepumpe und Wallbox; im Service-Bypass sperrt das EMS die Wallbox","ems":"Eigenes EMS (Home Assistant bzw. eigener Server, Börsenpreis und Prognose) über Modbus, der Failsafe-Ebene überlagert","p_min_14a_kW":4.2,"wallbox_14a_A":6,"eeg_pct":60,"eeg_kW":10.37,"netzgrenze_A":50,"insel_kW":16.5,"messkonzept":"§14a Modul 1 (optional zusätzlich Modul 3) auf einen Zähler; Stromwandler nach dem Zähler, vor der Aufteilung auf Wallbox und Deye","lastmanagement":{"grenze":"netzgrenze_A","empfehlung":true,"stufen":[{"rang":0,"knoten":"Deye","art":"speicher","aktion":"entladen","hinweis":"Stützung, kein Abwurf: befreit den eigenen Ladestrom und liefert zusätzlich"},{"rang":1,"knoten":"Wallbox","art":"dimmen","aktion":"pause"},{"rang":2,"knoten":"Deye","art":"speicher","aktion":"laden_stop"},{"rang":3,"knoten":"Wärmepumpe","art":"schalten","nur_modus":"kuehlen"},{"rang":3,"knoten":"Heizstäbe","art":"schalten","nur_modus":"heizen"},{"rang":4,"knoten":"Wärmepumpe","art":"schalten","nur_modus":"heizen"}],"soc_min_pct":20,"src":"Reihenfolge: Entscheidung des Betreibers vom 07.09.2026 (Auto zuletzt, Batterieladung davor; Wärmepumpe beim Heizen zuletzt, beim Kühlen früher). Rang 0 ist unser Vorschlag. soc_min_pct 20 ist unsere Empfehlung und kein Datenblattwert: erzeugung.speicher nennt weder Entladetiefe noch Mindestladezustand."},"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"},"lichtkonzept":{"regel":"Ganzes Haus: Licht A (oben) über Tastdimmer; Licht B (unten, Sockelleiste) 24-V-Band über Präsenzmelder","steuerstellen":"Alle Steuerstellen 3-adrig (L, N, PE) — Dimmer und Melder brauchen den Neutralleiter","treiber_24V":"Belüftete, zugängliche Nische oder über abgehängter Decke — nicht einmauern","linien_je_zone":2,"src":"Planungsdokument v19 (Kirschstr41), Stand 05.09.2026"}}